Does a C-or-better EPC sell for more in E1W 2 (Tower Hamlets)?

No premium here: C+ homes sold for slightly less. In postcode sector E1W 2 (Tower Hamlets), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 7.9% less (95% range −11.9% to −3.8%). The raw gap is bigger: C+ homes sold for 63% more per square metre than D–G homes (median £13,967 vs £8,554, 1,339 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−7.9% ▼like-for-like: small discount (95% range −11.9% to −3.8%)
+63%raw gap per m² (before like-for-like)
1,339sales matched to a certificate
63%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 75 m² against 67 m² for D–G; the most common build period is 2012 onwards for C+ and 1983–1990 for D–G; 0% of C+ and 1% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+63%—
Whole price, nothing held equal+41.2%+31.9% to +51.2%
Same floor area+35.1%+29.8% to +40.7%
+ same property type+34.7%+29.3% to +40.3%
+ same build period−6.4%−10.1% to −2.5%
+ same year of sale−7.9%−11.9% to −3.8%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in E1W 2

EPC band (last certificate before sale)SalesMedian £ per m²
B832£14,812
C306£8,437
D156£8,480
E34£9,171
F8too few
G3too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached0—2—
Terraced60£10,05325£10,270
Flat / maisonette1,078£14,119174£8,410

Compared with the wider area

AreaSalesLike-for-like95% range
Sector E1W 21,339−7.9%−11.9% to −3.8%
District E1W2,352−2.4%−5.4% to +0.7%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in E1W 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)50 (818 meters)
Median gas use per meter (median of postcodes)7,457 kWh
Gas-heated homes with an EPC1,087
Energy implied by their certificates (median)11,320 kWh
Metered gas as a share of the certificate figure (median of 50 postcodes)63% (middle half 52%–76%)

Certificates by band imply: B 4,990 kWh (62 homes) · C 10,227 kWh (767 homes) · D 15,906 kWh (227 homes) · E 22,779 kWh (29 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in E1W 2?

About 720 of the 1,045 gas-heated homes with an energy certificate in E1W 2 (69%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 6 of the 16 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector16
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 3,810 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,240
Gas-heated homes with an EPC on these substations1,045 (96% of the sector's)
Of them, could switch within the spare capacity≈ 720 (69%)
…if each heat pump adds 3 kW (a cold snap)≈ 550 (52%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,339 of 1,496 house and flat sales in the sector since 2015 (90%) were matched to a certificate.

How this is calculated

Caveats