EPC Price Check

Does a C-or-better EPC sell for more in DN12 4 (Doncaster)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector DN12 4 (Doncaster), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district DN12 as a whole the like-for-like difference is +2.2% (95% range −0.2% to +4.7%). The raw gap is bigger: C+ homes sold for 67% more per square metre than D–G homes (median £1,765 vs £1,054, 432 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+2.2%like-for-like in district DN12 (95% range −0.2% to +4.7%); too few sales in this sector
+67%raw gap per m² (before like-for-like)
432sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 72 m² against 96 m² for D–G; the most common build period is 2012 onwards for C+ and 1967–1975 for D–G; 77% of C+ and 54% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in DN12 4

EPC band (last certificate before sale)SalesMedian £ per m²
B250£1,854
C74£1,285
D76£1,144
E27£852
F5too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached71£2,09618£2,328
Semi-detached177£1,79040£1,169
Terraced68£1,38546£769
Flat / maisonette8—4—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector DN12 4432too few—
District DN123,379+2.2%−0.2% to +4.7%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in DN12 4 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)109 (2,057 meters)
Median gas use per meter (median of postcodes)8,901 kWh
Gas-heated homes with an EPC1,635
Energy implied by their certificates (median)13,388 kWh
Metered gas as a share of the certificate figure (median of 106 postcodes)61% (middle half 52%–72%)

Certificates by band imply: B 6,346 kWh (277 homes) · C 12,382 kWh (596 homes) · D 16,287 kWh (689 homes) · E 29,174 kWh (67 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in DN12 4?

About 1,140 of the 1,322 gas-heated homes with an energy certificate in DN12 4 (86%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 4 of the 13 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector13
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 4,490 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,640
Gas-heated homes with an EPC on these substations1,322 (81% of the sector's)
Of them, could switch within the spare capacity≈ 1,140 (86%)
…if each heat pump adds 3 kW (a cold snap)≈ 820 (62%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

432 of 471 house and flat sales in the sector since 2015 (92%) were matched to a certificate.

How this is calculated

Caveats