EPC Price Check

Does a C-or-better EPC sell for more in DL8 5 (North Yorkshire)?

No measurable EPC premium here. In postcode sector DL8 5 (North Yorkshire), comparing like with like — same floor area, property type, build period and year of sale — the difference is −1.1% (95% range −5.5% to +3.5%): the EPC band itself is not reflected in sale prices here. The raw gap is different: C+ homes sold for 1% more per square metre than D–G homes (median £2,829 vs £2,803, 776 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−1.1%like-for-like: no measurable difference (95% range −5.5% to +3.5%)
+1%raw gap per m² (before like-for-like)
776sales matched to a certificate
62%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 88 m² against 91 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 79% of C+ and 76% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+1%—
Whole price, nothing held equal+2.8%−2.9% to +8.7%
Same floor area+2.7%−1.0% to +6.6%
+ same property type+4.2%+0.9% to +7.6%
+ same build period+4.1%−1.0% to +9.6%
+ same year of sale−1.1%−5.5% to +3.5%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in DL8 5

EPC band (last certificate before sale)SalesMedian £ per m²
A7too few
B155£2,848
C169£2,783
D263£2,927
E124£2,669
F46£2,500
G12£3,338

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached144£3,063224£3,083
Semi-detached116£2,832115£2,681
Terraced62£2,67194£2,322
Flat / maisonette9—12£2,251

Compared with the wider area

AreaSalesLike-for-like95% range
Sector DL8 5776−1.1%−5.5% to +3.5%
District DL83,443−3.3%−5.4% to −1.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in DL8 5 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)67 (1,167 meters)
Median gas use per meter (median of postcodes)12,011 kWh
Gas-heated homes with an EPC864
Energy implied by their certificates (median)18,785 kWh
Metered gas as a share of the certificate figure (median of 64 postcodes)62% (middle half 51%–73%)

Certificates by band imply: B 7,240 kWh (125 homes) · C 15,450 kWh (278 homes) · D 22,019 kWh (352 homes) · E 32,303 kWh (90 homes) · F 62,671 kWh (12 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in DL8 5?

About 710 of the 858 gas-heated homes with an energy certificate in DL8 5 (82%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 5 of the 33 local substations would fill up before every gas-heated home they supply could switch; 3 are already at or over capacity.

Local (street) substations serving homes in the sector33
Already at or over capacity3 (9%)
Their combined spare capacity (demand headroom)≈ 5,440 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 3,200
Gas-heated homes with an EPC on these substations858 (99% of the sector's)
Of them, could switch within the spare capacity≈ 710 (82%)
…if each heat pump adds 3 kW (a cold snap)≈ 610 (71%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

776 of 843 house and flat sales in the sector since 2015 (92%) were matched to a certificate.

How this is calculated

Caveats