EPC Price Check

Does a C-or-better EPC sell for more in DL4 1 (County Durham)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector DL4 1 (County Durham), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district DL4 as a whole the like-for-like difference is +4.6% (95% range −0.5% to +9.9%). The raw gap is bigger: C+ homes sold for 59% more per square metre than D–G homes (median £1,106 vs £696, 709 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.6%like-for-like in district DL4 (95% range −0.5% to +9.9%); too few sales in this sector
+59%raw gap per m² (before like-for-like)
709sales matched to a certificate
53%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 84 m² against 85 m² for D–G; both groups are most often built in 1900–1929; 43% of C+ and 25% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in DL4 1

EPC band (last certificate before sale)SalesMedian £ per m²
A1too few
B18£1,418
C155£1,051
D354£739
E153£667
F19£620
G9too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached34£1,69244£1,612
Semi-detached40£1,38091£1,136
Terraced92£859399£641
Flat / maisonette8—1—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector DL4 1709too few—
District DL41,698+4.6%−0.5% to +9.9%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in DL4 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)112 (2,185 meters)
Median gas use per meter (median of postcodes)10,624 kWh
Gas-heated homes with an EPC1,649
Energy implied by their certificates (median)17,968 kWh
Metered gas as a share of the certificate figure (median of 110 postcodes)53% (middle half 45%–68%)

Certificates by band imply: B 7,096 kWh (53 homes) · C 13,728 kWh (608 homes) · D 20,040 kWh (752 homes) · E 31,175 kWh (212 homes) · F 43,781 kWh (18 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in DL4 1?

About 1,360 of the 1,517 gas-heated homes with an energy certificate in DL4 1 (90%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 6 of the 18 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector18
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 5,940 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 3,500
Gas-heated homes with an EPC on these substations1,517 (92% of the sector's)
Of them, could switch within the spare capacity≈ 1,360 (90%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,110 (73%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

709 of 747 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats