EPC Price Check

Does a C-or-better EPC sell for more in CO16 7 (Tendring)?

No measurable EPC premium here. In postcode sector CO16 7 (Tendring), comparing like with like — same floor area, property type, build period and year of sale — the difference is +0.2% (95% range −2.1% to +2.5%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 0% less per square metre than D–G homes (median £2,785 vs £2,792, 727 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+0.2%like-for-like: no measurable difference (95% range −2.1% to +2.5%)
0%raw gap per m² (before like-for-like)
727sales matched to a certificate
56%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 70 m² against 64 m² for D–G; the most common build period is 1983–1990 for C+ and 1976–1982 for D–G; 64% of C+ and 67% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)0%—
Whole price, nothing held equal+3.7%−1.6% to +9.3%
Same floor area+0.9%−3.1% to +5.0%
+ same property type+4.9%+1.5% to +8.3%
+ same build period+4.0%+0.7% to +7.5%
+ same year of sale+0.2%−2.1% to +2.5%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in CO16 7

EPC band (last certificate before sale)SalesMedian £ per m²
B11£2,724
C258£2,790
D396£2,810
E56£2,748
F6too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached102£2,943222£3,005
Semi-detached70£3,17884£2,915
Terraced58£2,603109£2,667
Flat / maisonette39£2,42243£2,167

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CO16 7727+0.2%−2.1% to +2.5%
District CO165,4440.0%−1.6% to +1.5%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CO16 7 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)90 (1,875 meters)
Median gas use per meter (median of postcodes)8,063 kWh
Gas-heated homes with an EPC1,342
Energy implied by their certificates (median)13,763 kWh
Metered gas as a share of the certificate figure (median of 88 postcodes)56% (middle half 49%–65%)

Certificates by band imply: B 5,363 kWh (41 homes) · C 12,011 kWh (643 homes) · D 16,069 kWh (590 homes) · E 22,721 kWh (59 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CO16 7?

About 950 of the 1,336 gas-heated homes with an energy certificate in CO16 7 (71%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 14 of the 23 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector23
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 4,430 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,610
Gas-heated homes with an EPC on these substations1,336
Of them, could switch within the spare capacity≈ 950 (71%)
…if each heat pump adds 3 kW (a cold snap)≈ 630 (47%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

727 of 764 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats