EPC Price Check

Does a C-or-better EPC sell for more in CO1 1 (Colchester)?

A small premium for a better EPC here. In postcode sector CO1 1 (Colchester), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 3.4% more (95% range +0.6% to +6.3%). The raw gap is different: C+ homes sold for 2% more per square metre than D–G homes (median £3,200 vs £3,125, 1,358 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.4% ▲like-for-like: small premium (95% range +0.6% to +6.3%)
+2%raw gap per m² (before like-for-like)
1,358sales matched to a certificate
62%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 60 m² against 71 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 16% of C+ and 27% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+2%—
Whole price, nothing held equal−4.8%−8.5% to −0.9%
Same floor area+1.9%−0.7% to +4.6%
+ same property type+11.7%+9.1% to +14.5%
+ same build period+5.7%+2.7% to +8.9%
+ same year of sale+3.4%+0.6% to +6.3%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in CO1 1

EPC band (last certificate before sale)SalesMedian £ per m²
B285£3,654
C509£3,050
D361£3,170
E166£3,060
F31£2,927
G6too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached56£3,39425£3,779
Semi-detached68£4,004126£3,245
Terraced133£3,311250£3,320
Flat / maisonette537£3,077163£2,667

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CO1 11,358+3.4%+0.6% to +6.3%
District CO13,636+1.3%−0.5% to +3.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CO1 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)123 (2,375 meters)
Median gas use per meter (median of postcodes)7,788 kWh
Gas-heated homes with an EPC2,025
Energy implied by their certificates (median)10,087 kWh
Metered gas as a share of the certificate figure (median of 118 postcodes)62% (middle half 51%–78%)

Certificates by band imply: B 5,209 kWh (480 homes) · C 8,651 kWh (817 homes) · D 16,499 kWh (543 homes) · E 28,550 kWh (168 homes) · F 45,910 kWh (14 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CO1 1?

About 1,390 of the 1,722 gas-heated homes with an energy certificate in CO1 1 (81%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 5 of the 37 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector37
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 14,600 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 8,590
Gas-heated homes with an EPC on these substations1,722 (85% of the sector's)
Of them, could switch within the spare capacity≈ 1,390 (81%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,150 (67%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,358 of 1,586 house and flat sales in the sector since 2015 (86%) were matched to a certificate.

How this is calculated

Caveats