EPC Price Check

Does a C-or-better EPC sell for more in CB22 6 (South Cambridgeshire)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector CB22 6 (South Cambridgeshire), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district CB22 as a whole the like-for-like difference is +3.2% (95% range +1.5% to +5.0%). The raw gap is bigger: C+ homes sold for 9% more per square metre than D–G homes (median £4,477 vs £4,090, 166 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.2%like-for-like in district CB22 (95% range +1.5% to +5.0%); too few sales in this sector
+9%raw gap per m² (before like-for-like)
166sales matched to a certificate
66%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 121 m² against 109 m² for D–G; the most common build period is 2012 onwards for C+ and 1967–1975 for D–G; 89% of C+ and 86% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in CB22 6

EPC band (last certificate before sale)SalesMedian £ per m²
B38£4,570
C32£4,073
D70£3,958
E24£4,501
F2too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached38£4,49264£4,097
Semi-detached24£4,69819£4,541
Terraced8—13£3,527

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CB22 6166too few—
District CB223,907+3.2%+1.5% to +5.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CB22 6 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)21 (423 meters)
Median gas use per meter (median of postcodes)13,262 kWh
Gas-heated homes with an EPC278
Energy implied by their certificates (median)17,897 kWh
Metered gas as a share of the certificate figure (median of 20 postcodes)66% (middle half 58%–79%)

Certificates by band imply: B 6,661 kWh (66 homes) · C 16,232 kWh (82 homes) · D 21,189 kWh (101 homes) · E 31,994 kWh (25 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CB22 6?

About 240 of the 247 gas-heated homes with an energy certificate in CB22 6 (99%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 1 of the 9 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector9
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 1,480 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 870
Gas-heated homes with an EPC on these substations247 (89% of the sector's)
Of them, could switch within the spare capacity≈ 240 (99%)
…if each heat pump adds 3 kW (a cold snap)≈ 220 (89%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

166 of 181 house and flat sales in the sector since 2015 (92%) were matched to a certificate.

How this is calculated

Caveats