EPC Price Check

Does a C-or-better EPC sell for more in CA24 3 (Cumberland)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector CA24 3 (Cumberland), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district CA24 as a whole the like-for-like difference is +5.3% (95% range −6.4% to +18.5%). The raw gap is bigger: C+ homes sold for 41% more per square metre than D–G homes (median £1,365 vs £969, 195 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+5.3%like-for-like in district CA24 (95% range −6.4% to +18.5%); too few sales in this sector
+41%raw gap per m² (before like-for-like)
195sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 92 m² against 92 m² for D–G; both groups are most often built before 1900; 46% of C+ and 17% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in CA24 3

EPC band (last certificate before sale)SalesMedian £ per m²
B10£1,656
C29£1,359
D101£1,000
E41£934
F11£833
G3too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached11£1,32719£1,949
Semi-detached7—8—
Terraced19£1,206129£934
Flat / maisonette2—0—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CA24 3195too few—
District CA24195+5.3%−6.4% to +18.5%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CA24 3 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)23 (441 meters)
Median gas use per meter (median of postcodes)11,755 kWh
Gas-heated homes with an EPC290
Energy implied by their certificates (median)20,804 kWh
Metered gas as a share of the certificate figure (median of 22 postcodes)61% (middle half 50%–71%)

Certificates by band imply: A 7,047 kWh (10 homes) · B 15,109 kWh (22 homes) · C 14,782 kWh (66 homes) · D 20,727 kWh (143 homes) · E 33,792 kWh (40 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CA24 3?

About 30 of the 281 gas-heated homes with an energy certificate in CA24 3 (11%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 3 of the 15 local substations would fill up before every gas-heated home they supply could switch; 2 are already at or over capacity.

Local (street) substations serving homes in the sector15
Already at or over capacity2 (13%)
Their combined spare capacity (demand headroom)≈ 3,680 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,160
Gas-heated homes with an EPC on these substations281 (97% of the sector's)
Of them, could switch within the spare capacity≈ 30 (11%)
…if each heat pump adds 3 kW (a cold snap)≈ 20 (9%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

195 of 209 house and flat sales in the sector since 2015 (93%) were matched to a certificate.

How this is calculated

Caveats