EPC Price Check

Does a C-or-better EPC sell for more in CA22 2 (Cumberland)?

A small premium for a better EPC here. In postcode sector CA22 2 (Cumberland), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 4.8% more (95% range +1.4% to +8.3%). The raw gap is bigger: C+ homes sold for 23% more per square metre than D–G homes (median £1,556 vs £1,262, 1,311 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.8% ▲like-for-like: small premium (95% range +1.4% to +8.3%)
+23%raw gap per m² (before like-for-like)
1,311sales matched to a certificate
52%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 84 m² against 86 m² for D–G; both groups are most often built in 1950–1966; 60% of C+ and 53% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+23%—
Whole price, nothing held equal+23.5%+16.2% to +31.3%
Same floor area+23.5%+17.8% to +29.5%
+ same property type+15.8%+11.7% to +20.0%
+ same build period+7.2%+3.5% to +10.9%
+ same year of sale+4.8%+1.4% to +8.3%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in CA22 2

EPC band (last certificate before sale)SalesMedian £ per m²
B50£2,188
C341£1,498
D627£1,333
E220£1,153
F55£1,186
G18£763

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached125£2,202186£1,924
Semi-detached110£1,758305£1,222
Terraced136£1,190418£1,111
Flat / maisonette20£1,17111£1,281

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CA22 21,311+4.8%+1.4% to +8.3%
District CA221,311+4.8%+1.4% to +8.3%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CA22 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)201 (3,811 meters)
Median gas use per meter (median of postcodes)10,777 kWh
Gas-heated homes with an EPC2,445
Energy implied by their certificates (median)18,478 kWh
Metered gas as a share of the certificate figure (median of 191 postcodes)52% (middle half 45%–62%)

Certificates by band imply: B 8,107 kWh (104 homes) · C 14,257 kWh (896 homes) · D 20,842 kWh (1,153 homes) · E 34,683 kWh (259 homes) · F 45,765 kWh (29 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CA22 2?

About 2,290 of the 2,444 gas-heated homes with an energy certificate in CA22 2 (94%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 5 of the 74 local substations would fill up before every gas-heated home they supply could switch; 1 is already at or over capacity.

Local (street) substations serving homes in the sector74
Already at or over capacity1 (1%)
Their combined spare capacity (demand headroom)≈ 11,540 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 6,790
Gas-heated homes with an EPC on these substations2,444
Of them, could switch within the spare capacity≈ 2,290 (94%)
…if each heat pump adds 3 kW (a cold snap)≈ 2,010 (82%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,311 of 1,364 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats