EPC Price Check

Does a C-or-better EPC sell for more in CA13 0 (Cumberland)?

A small premium for a better EPC here. In postcode sector CA13 0 (Cumberland), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 6.2% more (95% range +2.6% to +9.9%). The raw gap is bigger: C+ homes sold for 13% more per square metre than D–G homes (median £2,402 vs £2,119, 1,898 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+6.2% ▲like-for-like: small premium (95% range +2.6% to +9.9%)
+13%raw gap per m² (before like-for-like)
1,898sales matched to a certificate
55%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 90 m² against 96 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 70% of C+ and 59% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+13%—
Whole price, nothing held equal+8.7%+3.9% to +13.7%
Same floor area+12.4%+9.4% to +15.4%
+ same property type+8.8%+6.3% to +11.4%
+ same build period+7.3%+3.5% to +11.2%
+ same year of sale+6.2%+2.6% to +9.9%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in CA13 0

EPC band (last certificate before sale)SalesMedian £ per m²
B431£2,476
C427£2,348
D692£2,218
E253£1,908
F67£1,908
G28£1,902

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached346£2,547359£2,467
Semi-detached254£2,422258£2,154
Terraced133£2,149349£1,799
Flat / maisonette125£2,26774£2,000

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CA13 01,898+6.2%+2.6% to +9.9%
District CA133,208+1.2%−1.2% to +3.6%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CA13 0 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)168 (3,238 meters)
Median gas use per meter (median of postcodes)10,603 kWh
Gas-heated homes with an EPC2,290
Energy implied by their certificates (median)18,038 kWh
Metered gas as a share of the certificate figure (median of 157 postcodes)55% (middle half 46%–65%)

Certificates by band imply: B 8,442 kWh (420 homes) · C 13,427 kWh (648 homes) · D 21,743 kWh (957 homes) · E 35,363 kWh (227 homes) · F 53,352 kWh (31 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CA13 0?

About 1,820 of the 2,290 gas-heated homes with an energy certificate in CA13 0 (80%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 11 of the 113 local substations would fill up before every gas-heated home they supply could switch; 6 are already at or over capacity.

Local (street) substations serving homes in the sector113
Already at or over capacity6 (5%)
Their combined spare capacity (demand headroom)≈ 11,380 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 6,690
Gas-heated homes with an EPC on these substations2,290
Of them, could switch within the spare capacity≈ 1,820 (80%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,590 (69%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,898 of 2,040 house and flat sales in the sector since 2015 (93%) were matched to a certificate.

How this is calculated

Caveats