EPC Price Check

Does a C-or-better EPC sell for more in BL2 1 (Bolton)?

A small premium for a better EPC here. In postcode sector BL2 1 (Bolton), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 6.8% more (95% range +2.1% to +11.7%). The raw gap is bigger: C+ homes sold for 60% more per square metre than D–G homes (median £2,431 vs £1,520, 501 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+6.8% ▲like-for-like: small premium (95% range +2.1% to +11.7%)
+60%raw gap per m² (before like-for-like)
501sales matched to a certificate
59%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 80 m² against 82 m² for D–G; the most common build period is 2012 onwards for C+ and 1900–1929 for D–G; 62% of C+ and 46% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+60%—
Whole price, nothing held equal+37.6%+26.9% to +49.3%
Same floor area+39.2%+30.0% to +49.1%
+ same property type+23.6%+16.6% to +31.1%
+ same build period+12.8%+6.1% to +19.9%
+ same year of sale+6.8%+2.1% to +11.7%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in BL2 1

EPC band (last certificate before sale)SalesMedian £ per m²
B75£2,532
C105£1,836
D243£1,568
E58£1,259
F16£1,197
G4too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached60£2,53927£1,938
Semi-detached52£2,356120£1,789
Terraced50£1,684140£1,158
Flat / maisonette18£1,85534£1,730

Compared with the wider area

AreaSalesLike-for-like95% range
Sector BL2 1501+6.8%+2.1% to +11.7%
District BL26,551−0.3%−1.8% to +1.3%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in BL2 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)76 (1,603 meters)
Median gas use per meter (median of postcodes)10,489 kWh
Gas-heated homes with an EPC1,215
Energy implied by their certificates (median)16,273 kWh
Metered gas as a share of the certificate figure (median of 73 postcodes)59% (middle half 51%–75%)

Certificates by band imply: B 8,347 kWh (115 homes) · C 13,496 kWh (449 homes) · D 19,067 kWh (511 homes) · E 33,380 kWh (113 homes) · F 48,845 kWh (23 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in BL2 1?

About 990 of the 1,215 gas-heated homes with an energy certificate in BL2 1 (82%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 1 of the 21 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector21
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 12,220 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 7,190
Gas-heated homes with an EPC on these substations1,215
Of them, could switch within the spare capacity≈ 990 (82%)
…if each heat pump adds 3 kW (a cold snap)≈ 890 (73%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

501 of 529 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats