EPC Price Check

Does a C-or-better EPC sell for more in BD24 0 (North Yorkshire)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector BD24 0 (North Yorkshire), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district BD24 as a whole the like-for-like difference is +3.0% (95% range −0.8% to +6.8%). The raw gap is bigger: C+ homes sold for 11% more per square metre than D–G homes (median £2,943 vs £2,647, 329 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.0%like-for-like in district BD24 (95% range −0.8% to +6.8%); too few sales in this sector
+11%raw gap per m² (before like-for-like)
329sales matched to a certificate
56%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 106 m² against 96 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 63% of C+ and 66% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in BD24 0

EPC band (last certificate before sale)SalesMedian £ per m²
A11£4,043
B43£2,683
C58£3,069
D109£2,787
E65£2,575
F32£2,369
G11£2,500

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached50£3,22085£3,035
Semi-detached21£3,29558£2,549
Terraced35£2,66773£2,449
Flat / maisonette6—1—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector BD24 0329too few—
District BD241,060+3.0%−0.8% to +6.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in BD24 0 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)29 (464 meters)
Median gas use per meter (median of postcodes)12,222 kWh
Gas-heated homes with an EPC346
Energy implied by their certificates (median)19,419 kWh
Metered gas as a share of the certificate figure (median of 25 postcodes)56% (middle half 50%–68%)

Certificates by band imply: A 5,843 kWh (34 homes) · B 7,905 kWh (42 homes) · C 17,708 kWh (107 homes) · D 23,523 kWh (132 homes) · E 40,204 kWh (28 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in BD24 0?

About 320 of the 345 gas-heated homes with an energy certificate in BD24 0 (92%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 2 of the 62 local substations would fill up before every gas-heated home they supply could switch; 4 are already at or over capacity.

Local (street) substations serving homes in the sector62
Already at or over capacity4 (6%)
Their combined spare capacity (demand headroom)≈ 3,870 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,280
Gas-heated homes with an EPC on these substations345
Of them, could switch within the spare capacity≈ 320 (92%)
…if each heat pump adds 3 kW (a cold snap)≈ 280 (81%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

329 of 381 house and flat sales in the sector since 2015 (86%) were matched to a certificate.

How this is calculated

Caveats