Does a C-or-better EPC sell for more in BB10 3 (Burnley)?

A small premium for a better EPC here. In postcode sector BB10 3 (Burnley), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 6.8% more (95% range +0.7% to +13.3%). The raw gap is bigger: C+ homes sold for 69% more per square metre than D–G homes (median £2,052 vs £1,212, 1,340 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+6.8% ▲like-for-like: small premium (95% range +0.7% to +13.3%)
+69%raw gap per m² (before like-for-like)
1,340sales matched to a certificate
55%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 85 m² against 84 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 69% of C+ and 37% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+69%—
Whole price, nothing held equal+73.4%+58.7% to +89.5%
Same floor area+63.5%+52.2% to +75.7%
+ same property type+27.5%+20.5% to +35.0%
+ same build period+14.4%+7.4% to +21.8%
+ same year of sale+6.8%+0.7% to +13.3%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in BB10 3

EPC band (last certificate before sale)SalesMedian £ per m²
A3too few
B48£3,702
C191£1,842
D741£1,380
E284£986
F57£760
G16£684

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached86£2,834162£2,215
Semi-detached80£2,267249£1,806
Terraced74£1,299683£855
Flat / maisonette2—4—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector BB10 31,340+6.8%+0.7% to +13.3%
District BB106,408+1.9%−0.5% to +4.5%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in BB10 3 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)151 (3,321 meters)
Median gas use per meter (median of postcodes)11,578 kWh
Gas-heated homes with an EPC2,557
Energy implied by their certificates (median)20,244 kWh
Metered gas as a share of the certificate figure (median of 147 postcodes)55% (middle half 47%–64%)

Certificates by band imply: A 5,992 kWh (70 homes) · B 7,116 kWh (64 homes) · C 13,486 kWh (702 homes) · D 21,386 kWh (1,193 homes) · E 31,263 kWh (462 homes) · F 42,313 kWh (59 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in BB10 3?

About 2,170 of the 2,557 gas-heated homes with an energy certificate in BB10 3 (85%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 8 of the 64 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector64
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 10,770 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 6,340
Gas-heated homes with an EPC on these substations2,557
Of them, could switch within the spare capacity≈ 2,170 (85%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,700 (66%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,340 of 1,423 house and flat sales in the sector since 2015 (94%) were matched to a certificate.

How this is calculated

Caveats