EPC Price Check

Solar panels, heat pumps and insulation in Fish Island conservation area

In the Fish Island conservation area (Tower Hamlets), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 245 homes inside the boundary have an energy certificate: 24.5% are solid-wall homes with no wall insulation, 24.5% heat with a gas boiler and 8.2% are rated D–G; 3 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

245homes with an energy certificate
24.5%solid walls, no insulation
24.5%heated by a gas boiler
3heat pumps

Article 4: Tower Hamlets publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Fish Island

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 245)

WallsHomesShare
Modern wall (U-value from the design)11245.7%
Other or not known6325.7%
Solid wall (brick or stone), no insulation6024.5%
Cavity wall, insulated (as built or unspecified)41.6%
Solid wall, insulated20.8%
Solid wall, internal insulation20.8%
Cavity wall, unfilled10.4%
Timber frame10.4%
HeatingHomesShare
Electric (storage heaters, panels, boiler)9840.0%
Communal heating8333.9%
Gas boiler6024.5%
Heat pump31.2%
Other10.4%
Loft / roof insulationHomesShare
No insulation20.8%
Insulated (depth not recorded)176.9%
Flat or other home above19680.0%
Other3012.2%
WindowsHomesShare
Double glazed24399.2%
Other10.4%
Single glazed10.4%

Energy rating: B 123 (50.2%) · C 102 (41.6%) · D 11 (4.5%) · E 9 (3.7%). Houses and bungalows: 1% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 2021.

Compared with Tower Hamlets and England

Share of homesFish IslandAll 61 areas in Tower HamletsEngland
Solid walls, no insulation24.5%41.8%48.7%
Gas boiler24.5%61.1%66.4%
Rated D–G8.2%—56.5%

Caveats

All conservation areas in Tower Hamlets · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker