Solar panels, heat pumps and insulation in Hackney Wick conservation area

In the Hackney Wick conservation area (Hackney), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Hackney covers this area but deals with other things (such as changes of use); it does not change the rules below. 226 homes inside the boundary have an energy certificate: 8.0% are solid-wall homes with no wall insulation, 28.8% heat with a gas boiler and 10.6% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

226homes with an energy certificate
8.0%solid walls, no insulation
28.8%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Hackney covers this area but deals with other things (such as changes of use); it does not change the rules below. (London borough of Hackney)

What needs planning permission in Hackney Wick

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 226)

WallsHomesShare
Modern wall (U-value from the design)17276.1%
Cavity wall, unfilled3214.2%
Solid wall (brick or stone), no insulation188.0%
Cavity wall, insulated (as built or unspecified)41.8%
HeatingHomesShare
Communal heating16070.8%
Gas boiler6528.8%
Electric (storage heaters, panels, boiler)10.4%
Loft / roof insulationHomesShare
No insulation83.5%
Under 200 mm31.3%
Insulated (depth not recorded)104.4%
Flat or other home above14363.3%
Other6227.4%
WindowsHomesShare
Double glazed17979.2%
Single glazed4519.9%
Triple glazed20.9%

Energy rating: B 177 (78.3%) · C 25 (11.1%) · D 16 (7.1%) · E 7 (3.1%) · G 1 (0.4%). Houses and bungalows: 0% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 2018. Designated: 1 January 2009.

Compared with Hackney and England

Share of homesHackney WickAll 37 areas in HackneyEngland
Solid walls, no insulation8.0%50.5%48.7%
Gas boiler28.8%70.8%66.4%
Rated D–G10.6%—56.5%

Caveats

All conservation areas in Hackney · The rules for every conservation area