Solar panels, heat pumps and insulation in Dawlish conservation area

In the Dawlish conservation area (Teignbridge), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 83 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,403 homes inside the boundary have an energy certificate: 52.1% are solid-wall homes with no wall insulation, 68.9% heat with a gas boiler and 57.2% are rated D–G; 11 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,403homes with an energy certificate
52.1%solid walls, no insulation
68.9%heated by a gas boiler
11heat pumps

Article 4: Teignbridge does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Dawlish

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,403)

WallsHomesShare
Solid wall (brick or stone), no insulation73152.1%
Cavity wall, insulated (as built or unspecified)23116.5%
Timber frame1027.3%
Cavity wall, unfilled946.7%
Cavity wall, filled896.3%
Modern wall (U-value from the design)513.6%
Solid wall, insulated352.5%
Cavity wall, partly insulated322.3%
Solid wall, internal insulation282.0%
Cavity wall, internal or external insulation30.2%
Other or not known30.2%
Solid wall, partly insulated30.2%
Solid wall, external insulation10.1%
HeatingHomesShare
Gas boiler96768.9%
Electric (storage heaters, panels, boiler)39328.0%
Communal heating271.9%
Heat pump110.8%
Solid fuel (wood, coal)40.3%
LPG10.1%
Loft / roof insulationHomesShare
No insulation18613.3%
Under 200 mm28320.2%
200 mm or more31122.2%
Insulated (depth not recorded)14410.3%
Flat or other home above43931.3%
Other402.9%
WindowsHomesShare
Double glazed1,26390.0%
Single glazed1168.3%
Secondary glazing231.6%
Triple glazed10.1%

Energy rating: A 3 (0.2%) · B 57 (4.1%) · C 540 (38.5%) · D 534 (38.1%) · E 205 (14.6%) · F 46 (3.3%) · G 18 (1.3%). Houses and bungalows: 44% of the homes; solar panels on 0.7% of the certificates. Most common build period on the certificates: before 1900.

Compared with Teignbridge and England

Share of homesDawlishAll 35 areas in TeignbridgeEngland
Solid walls, no insulation52.1%56.0%48.7%
Gas boiler68.9%65.7%66.4%
Rated D–G57.2%—56.5%