EPC Price Check

Solar panels, heat pumps and insulation in Teignmouth St James conservation area

In the Teignmouth St James conservation area (Teignbridge), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 6 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 202 homes inside the boundary have an energy certificate: 57.9% are solid-wall homes with no wall insulation, 76.2% heat with a gas boiler and 63.9% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

202homes with an energy certificate
57.9%solid walls, no insulation
76.2%heated by a gas boiler
1heat pumps

Article 4: Teignbridge does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Teignmouth St James

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 202)

WallsHomesShare
Solid wall (brick or stone), no insulation11757.9%
Modern wall (U-value from the design)188.9%
Cavity wall, insulated (as built or unspecified)167.9%
Timber frame125.9%
Cavity wall, unfilled115.4%
Solid wall, internal insulation105.0%
Cavity wall, filled63.0%
Cavity wall, partly insulated52.5%
Other or not known21.0%
Solid wall, insulated21.0%
Solid wall, partly insulated21.0%
Cavity wall, internal or external insulation10.5%
HeatingHomesShare
Gas boiler15476.2%
Electric (storage heaters, panels, boiler)4019.8%
Communal heating73.5%
Heat pump10.5%
Loft / roof insulationHomesShare
No insulation3215.8%
Under 200 mm4522.3%
200 mm or more3517.3%
Insulated (depth not recorded)2713.4%
Flat or other home above4823.8%
Other157.4%
WindowsHomesShare
Double glazed19697.0%
Single glazed63.0%

Energy rating: B 8 (4.0%) · C 65 (32.2%) · D 71 (35.1%) · E 44 (21.8%) · F 10 (5.0%) · G 4 (2.0%). Houses and bungalows: 55% of the homes; solar panels on 0.5% of the certificates. Most common build period on the certificates: before 1900. Designated: 15 November 1994.

Compared with Teignbridge and England

Share of homesTeignmouth St JamesAll 35 areas in TeignbridgeEngland
Solid walls, no insulation57.9%56.0%48.7%
Gas boiler76.2%65.7%66.4%
Rated D–G63.9%—56.5%

Caveats

All conservation areas in Teignbridge · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker