Solar panels, heat pumps and insulation in The Avenue conservation area

In the The Avenue conservation area (Southampton), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Southampton covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 3 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 364 homes inside the boundary have an energy certificate: 8.0% are solid-wall homes with no wall insulation, 74.2% heat with a gas boiler and 28.3% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

364homes with an energy certificate
8.0%solid walls, no insulation
74.2%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Southampton covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (HMO; The Avenue Conservation Area)

What needs planning permission in The Avenue

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 364)

WallsHomesShare
Cavity wall, insulated (as built or unspecified)12634.6%
Modern wall (U-value from the design)7520.6%
Cavity wall, filled5314.6%
Cavity wall, unfilled4813.2%
Solid wall (brick or stone), no insulation298.0%
Timber frame184.9%
Other or not known71.9%
Cavity wall, partly insulated51.4%
Solid wall, insulated30.8%
HeatingHomesShare
Gas boiler27074.2%
Electric (storage heaters, panels, boiler)8824.2%
Communal heating61.6%
Loft / roof insulationHomesShare
No insulation164.4%
Under 200 mm308.2%
200 mm or more256.9%
Insulated (depth not recorded)3910.7%
Flat or other home above20255.5%
Other5214.3%
WindowsHomesShare
Double glazed33491.8%
Single glazed256.9%
Secondary glazing51.4%

Energy rating: B 90 (24.7%) · C 171 (47.0%) · D 77 (21.2%) · E 21 (5.8%) · F 5 (1.4%). Houses and bungalows: 14% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 2007-2011. Designated: 2 January 1975.

Compared with Southampton and England

Share of homesThe AvenueAll 21 areas in SouthamptonEngland
Solid walls, no insulation8.0%16.0%48.7%
Gas boiler74.2%42.8%66.4%
Rated D–G28.3%—56.5%