Solar panels, heat pumps and insulation in Carlton Crescent conservation area

In the Carlton Crescent conservation area (Southampton), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Southampton covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 38 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 429 homes inside the boundary have an energy certificate: 26.3% are solid-wall homes with no wall insulation, 38.9% heat with a gas boiler and 40.8% are rated D–G; 8 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

429homes with an energy certificate
26.3%solid walls, no insulation
38.9%heated by a gas boiler
8heat pumps

Article 4: An Article 4 direction published by Southampton covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (Carlton Crescent Conservation Area; HMO)

What needs planning permission in Carlton Crescent

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 429)

WallsHomesShare
Solid wall (brick or stone), no insulation11326.3%
Modern wall (U-value from the design)9522.1%
Cavity wall, insulated (as built or unspecified)7116.6%
Cavity wall, partly insulated4811.2%
Cavity wall, unfilled358.2%
Timber frame255.8%
Cavity wall, internal or external insulation184.2%
Solid wall, insulated122.8%
Cavity wall, filled40.9%
Solid wall, internal insulation40.9%
Other or not known20.5%
Solid wall, external insulation10.2%
Solid wall, partly insulated10.2%
HeatingHomesShare
Electric (storage heaters, panels, boiler)22452.2%
Gas boiler16738.9%
Communal heating296.8%
Heat pump81.9%
LPG10.2%
Loft / roof insulationHomesShare
No insulation378.6%
Under 200 mm327.5%
200 mm or more286.5%
Insulated (depth not recorded)6414.9%
Flat or other home above23855.5%
Other307.0%
WindowsHomesShare
Double glazed35883.4%
Single glazed6815.9%
Secondary glazing30.7%

Energy rating: B 74 (17.2%) · C 180 (42.0%) · D 126 (29.4%) · E 45 (10.5%) · F 1 (0.2%) · G 3 (0.7%). Houses and bungalows: 14% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 19 October 1972.

Compared with Southampton and England

Share of homesCarlton CrescentAll 21 areas in SouthamptonEngland
Solid walls, no insulation26.3%16.0%48.7%
Gas boiler38.9%42.8%66.4%
Rated D–G40.8%—56.5%

Caveats

All conservation areas in Southampton · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker