EPC Price Check

Solar panels, heat pumps and insulation in Burnham Market conservation area

In the Burnham Market conservation area (King's Lynn and West Norfolk), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 58 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 205 homes inside the boundary have an energy certificate: 44.9% are solid-wall homes with no wall insulation, 0.0% heat with a gas boiler and 80.0% are rated D–G; 31 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

205homes with an energy certificate
44.9%solid walls, no insulation
0.0%heated by a gas boiler
31heat pumps

Article 4: King's Lynn and West Norfolk publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Burnham Market

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 205)

WallsHomesShare
Solid wall (brick or stone), no insulation9244.9%
Cavity wall, insulated (as built or unspecified)4120.0%
Modern wall (U-value from the design)2914.1%
Solid wall, insulated178.3%
Solid wall, internal insulation115.4%
Cavity wall, filled83.9%
Cavity wall, partly insulated31.5%
Cavity wall, internal or external insulation21.0%
Cavity wall, unfilled10.5%
Solid wall, partly insulated10.5%
HeatingHomesShare
Oil8742.4%
Electric (storage heaters, panels, boiler)8340.5%
Heat pump3115.1%
LPG31.5%
Communal heating10.5%
Loft / roof insulationHomesShare
No insulation199.3%
Under 200 mm5225.4%
200 mm or more7134.6%
Insulated (depth not recorded)3416.6%
Other2914.1%
WindowsHomesShare
Double glazed17183.4%
Single glazed2311.2%
Secondary glazing115.4%

Energy rating: B 17 (8.3%) · C 24 (11.7%) · D 55 (26.8%) · E 79 (38.5%) · F 22 (10.7%) · G 8 (3.9%). Houses and bungalows: 96% of the homes; solar panels on 0.5% of the certificates. Most common build period on the certificates: before 1900. Designated: 24 July 1975.

Compared with King's Lynn and West Norfolk and England

Share of homesBurnham MarketAll 43 areas in King's Lynn and West NorfolkEngland
Solid walls, no insulation44.9%48.8%48.7%
Gas boiler0.0%35.4%66.4%
Rated D–G80.0%—56.5%

Caveats

All conservation areas in King's Lynn and West Norfolk · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker