EPC Price Check

Solar panels, heat pumps and insulation in Philbeach (35) conservation area

In the Philbeach conservation area (Kensington and Chelsea), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. 501 homes inside the boundary have an energy certificate: 84.0% are solid-wall homes with no wall insulation, 77.8% heat with a gas boiler and 35.1% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

501homes with an energy certificate
84.0%solid walls, no insulation
77.8%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. (Article 4 - No 100; Article 4 - No 76)

What needs planning permission in Philbeach

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 501)

WallsHomesShare
Solid wall (brick or stone), no insulation42184.0%
Timber frame448.8%
Solid wall, internal insulation173.4%
Modern wall (U-value from the design)71.4%
Solid wall, partly insulated30.6%
Cavity wall, insulated (as built or unspecified)20.4%
Cavity wall, internal or external insulation20.4%
Cavity wall, unfilled20.4%
Other or not known20.4%
Cavity wall, partly insulated10.2%
HeatingHomesShare
Gas boiler39077.8%
Communal heating6913.8%
Electric (storage heaters, panels, boiler)428.4%
Loft / roof insulationHomesShare
No insulation7014.0%
Under 200 mm40.8%
200 mm or more30.6%
Insulated (depth not recorded)357.0%
Flat or other home above38476.6%
Other51.0%
WindowsHomesShare
Double glazed25751.3%
Single glazed22945.7%
Secondary glazing112.2%
Triple glazed40.8%

Energy rating: B 12 (2.4%) · C 313 (62.5%) · D 152 (30.3%) · E 20 (4.0%) · F 2 (0.4%) · G 2 (0.4%). Houses and bungalows: 2% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 January 1993.

Compared with Kensington and Chelsea and England

Share of homesPhilbeachAll 44 areas in Kensington and ChelseaEngland
Solid walls, no insulation84.0%79.7%48.7%
Gas boiler77.8%72.9%66.4%
Rated D–G35.1%—56.5%

Caveats

All conservation areas in Kensington and Chelsea · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker