Solar panels, heat pumps and insulation in Holland Park conservation area

In the Holland Park conservation area (Kensington and Chelsea), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. The area has 119 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,824 homes inside the boundary have an energy certificate: 67.1% are solid-wall homes with no wall insulation, 66.4% heat with a gas boiler and 58.4% are rated D–G; 6 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,824homes with an energy certificate
67.1%solid walls, no insulation
66.4%heated by a gas boiler
6heat pumps

Article 4: An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. (Article 4 - No 100; Article 4 - No 30; Article 4 - No 31; Article 4 - No 40; Article 4 - No 75)

What needs planning permission in Holland Park

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,824)

WallsHomesShare
Solid wall (brick or stone), no insulation1,22367.1%
Cavity wall, unfilled25914.2%
Modern wall (U-value from the design)784.3%
Other or not known764.2%
Cavity wall, insulated (as built or unspecified)422.3%
Timber frame422.3%
Cavity wall, partly insulated362.0%
Solid wall, internal insulation291.6%
Solid wall, partly insulated140.8%
Solid wall, insulated130.7%
Cavity wall, filled80.4%
Cavity wall, internal or external insulation20.1%
Solid wall, external insulation20.1%
HeatingHomesShare
Gas boiler1,21166.4%
Communal heating50327.6%
Electric (storage heaters, panels, boiler)1035.6%
Heat pump60.3%
Oil10.1%
Loft / roof insulationHomesShare
No insulation34218.8%
Under 200 mm734.0%
200 mm or more281.5%
Insulated (depth not recorded)27114.9%
Flat or other home above1,07258.8%
Other382.1%
WindowsHomesShare
Double glazed1,02656.2%
Single glazed65736.0%
Secondary glazing1357.4%
Triple glazed60.3%

Energy rating: A 1 (0.1%) · B 88 (4.8%) · C 670 (36.7%) · D 760 (41.7%) · E 272 (14.9%) · F 28 (1.5%) · G 5 (0.3%). Houses and bungalows: 26% of the homes; solar panels on 0.1% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1971.

Compared with Kensington and Chelsea and England

Share of homesHolland ParkAll 44 areas in Kensington and ChelseaEngland
Solid walls, no insulation67.1%79.7%48.7%
Gas boiler66.4%72.9%66.4%
Rated D–G58.4%—56.5%

Caveats

All conservation areas in Kensington and Chelsea · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker