Solar panels, heat pumps and insulation in De Vere conservation area

In the De Vere conservation area (Kensington and Chelsea), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. The area has 18 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 799 homes inside the boundary have an energy certificate: 77.8% are solid-wall homes with no wall insulation, 74.3% heat with a gas boiler and 60.6% are rated D–G; 10 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

799homes with an energy certificate
77.8%solid walls, no insulation
74.3%heated by a gas boiler
10heat pumps

Article 4: An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. (Article 4 - No 100; Article 4 - No 106; Article 4 - No 26; Article 4 - No 3; Article 4 - No 53; Article 4 - No 54)

What needs planning permission in De Vere

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 799)

WallsHomesShare
Solid wall (brick or stone), no insulation62277.8%
Solid wall, partly insulated293.6%
Modern wall (U-value from the design)273.4%
Cavity wall, insulated (as built or unspecified)263.3%
Timber frame222.8%
Solid wall, internal insulation192.4%
Other or not known182.3%
Cavity wall, unfilled172.1%
Solid wall, insulated101.3%
Cavity wall, partly insulated60.8%
Cavity wall, internal or external insulation30.4%
HeatingHomesShare
Gas boiler59474.3%
Communal heating13116.4%
Electric (storage heaters, panels, boiler)617.6%
Heat pump101.3%
LPG20.3%
Oil10.1%
Loft / roof insulationHomesShare
No insulation19124.0%
Under 200 mm546.8%
200 mm or more81.0%
Insulated (depth not recorded)10413.0%
Flat or other home above42252.9%
Other182.3%
WindowsHomesShare
Double glazed42052.6%
Single glazed31038.8%
Secondary glazing688.5%
Triple glazed10.1%

Energy rating: B 46 (5.8%) · C 269 (33.7%) · D 325 (40.7%) · E 138 (17.3%) · F 17 (2.1%) · G 4 (0.5%). Houses and bungalows: 31% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1969.

Compared with Kensington and Chelsea and England

Share of homesDe VereAll 44 areas in Kensington and ChelseaEngland
Solid walls, no insulation77.8%79.7%48.7%
Gas boiler74.3%72.9%66.4%
Rated D–G60.6%—56.5%

Caveats