EPC Price Check

Solar panels, heat pumps and insulation in Colville conservation area

In the Colville conservation area (Kensington and Chelsea), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Kensington and Chelsea covers this area but deals with other things (such as changes of use); it does not change the rules below. The area has 4 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,537 homes inside the boundary have an energy certificate: 73.4% are solid-wall homes with no wall insulation, 82.6% heat with a gas boiler and 45.5% are rated D–G; 4 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,537homes with an energy certificate
73.4%solid walls, no insulation
82.6%heated by a gas boiler
4heat pumps

Article 4: An Article 4 direction published by Kensington and Chelsea covers this area but deals with other things (such as changes of use); it does not change the rules below. (Article 4 - No 100; Article 4 - No 106)

What needs planning permission in Colville

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,537)

WallsHomesShare
Solid wall (brick or stone), no insulation1,12873.4%
Cavity wall, insulated (as built or unspecified)714.6%
Cavity wall, unfilled654.2%
Timber frame483.1%
Cavity wall, filled412.7%
Cavity wall, partly insulated392.5%
Solid wall, internal insulation362.3%
Modern wall (U-value from the design)342.2%
Solid wall, insulated271.8%
Other or not known241.6%
Solid wall, partly insulated120.8%
Solid wall, external insulation90.6%
Cavity wall, internal or external insulation30.2%
HeatingHomesShare
Gas boiler1,26982.6%
Electric (storage heaters, panels, boiler)16110.5%
Communal heating1036.7%
Heat pump40.3%
Loft / roof insulationHomesShare
No insulation22614.7%
Under 200 mm573.7%
200 mm or more241.6%
Insulated (depth not recorded)19012.4%
Flat or other home above1,01666.1%
Other241.6%
WindowsHomesShare
Double glazed84154.7%
Single glazed65142.4%
Secondary glazing442.9%
Triple glazed10.1%

Energy rating: B 43 (2.8%) · C 794 (51.7%) · D 538 (35.0%) · E 140 (9.1%) · F 21 (1.4%) · G 1 (0.1%). Houses and bungalows: 10% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 2004.

Compared with Kensington and Chelsea and England

Share of homesColvilleAll 44 areas in Kensington and ChelseaEngland
Solid walls, no insulation73.4%79.7%48.7%
Gas boiler82.6%72.9%66.4%
Rated D–G45.5%—56.5%

Caveats

All conservation areas in Kensington and Chelsea · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker