EPC Price Check

Solar panels, heat pumps and insulation in Newington Green conservation area

In the Newington Green conservation area (Islington), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 7 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,217 homes inside the boundary have an energy certificate: 82.4% are solid-wall homes with no wall insulation, 91.2% heat with a gas boiler and 45.5% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,217homes with an energy certificate
82.4%solid walls, no insulation
91.2%heated by a gas boiler
0heat pumps

Article 4: Islington does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Newington Green

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,217)

WallsHomesShare
Solid wall (brick or stone), no insulation1,00382.4%
Other or not known776.3%
Cavity wall, insulated (as built or unspecified)433.5%
Timber frame221.8%
Cavity wall, unfilled141.2%
Modern wall (U-value from the design)131.1%
Solid wall, insulated121.0%
Cavity wall, filled110.9%
Solid wall, partly insulated100.8%
Solid wall, internal insulation90.7%
Solid wall, external insulation20.2%
Cavity wall, partly insulated10.1%
HeatingHomesShare
Gas boiler1,11091.2%
Communal heating574.7%
Electric (storage heaters, panels, boiler)494.0%
Solid fuel (wood, coal)10.1%
Loft / roof insulationHomesShare
No insulation19916.4%
Under 200 mm1139.3%
200 mm or more443.6%
Insulated (depth not recorded)13611.2%
Flat or other home above71458.7%
Other110.9%
WindowsHomesShare
Double glazed73660.5%
Single glazed43535.7%
Secondary glazing423.5%
Triple glazed40.3%

Energy rating: B 19 (1.6%) · C 644 (52.9%) · D 479 (39.4%) · E 69 (5.7%) · F 2 (0.2%) · G 4 (0.3%). Houses and bungalows: 12% of the homes; solar panels on 0.1% of the certificates. Most common build period on the certificates: 1900-1929.

Compared with Islington and England

Share of homesNewington GreenAll 41 areas in IslingtonEngland
Solid walls, no insulation82.4%67.1%48.7%
Gas boiler91.2%79.1%66.4%
Rated D–G45.5%—56.5%

Caveats

All conservation areas in Islington · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker