EPC Price Check

Solar panels, heat pumps and insulation in De Beauvoir conservation area

In the De Beauvoir conservation area (Hackney), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Hackney covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. The area has 31 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,513 homes inside the boundary have an energy certificate: 52.5% are solid-wall homes with no wall insulation, 88.6% heat with a gas boiler and 49.7% are rated D–G; 9 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,513homes with an energy certificate
52.5%solid walls, no insulation
88.6%heated by a gas boiler
9heat pumps

Article 4: An Article 4 direction published by Hackney covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), painting the outside, so there these need planning permission too. (A4D Non-residential to residential; Dalston; De Beauvoir; De Beauvoir Conservation Area (article 4 direction area); London borough of Hackney; Priority Industrial Area - De Beauvoir)

What needs planning permission in De Beauvoir

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,513)

WallsHomesShare
Solid wall (brick or stone), no insulation79452.5%
Cavity wall, insulated (as built or unspecified)27818.4%
Cavity wall, unfilled1238.1%
Cavity wall, filled724.8%
Modern wall (U-value from the design)553.6%
Other or not known543.6%
Solid wall, internal insulation432.8%
Solid wall, insulated281.9%
Cavity wall, partly insulated271.8%
Timber frame241.6%
Solid wall, partly insulated70.5%
Solid wall, external insulation50.3%
Cavity wall, internal or external insulation30.2%
HeatingHomesShare
Gas boiler1,34088.6%
Electric (storage heaters, panels, boiler)1318.7%
Communal heating302.0%
Heat pump90.6%
LPG30.2%
Loft / roof insulationHomesShare
No insulation23115.3%
Under 200 mm29919.8%
200 mm or more1419.3%
Insulated (depth not recorded)25516.9%
Flat or other home above54536.0%
Other412.7%
WindowsHomesShare
Double glazed1,10873.2%
Single glazed37024.5%
Secondary glazing342.2%
Triple glazed10.1%

Energy rating: A 1 (0.1%) · B 67 (4.4%) · C 693 (45.8%) · D 595 (39.3%) · E 142 (9.4%) · F 13 (0.9%) · G 2 (0.1%). Houses and bungalows: 41% of the homes; solar panels on 0.3% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1971.

Compared with Hackney and England

Share of homesDe BeauvoirAll 37 areas in HackneyEngland
Solid walls, no insulation52.5%50.5%48.7%
Gas boiler88.6%70.8%66.4%
Rated D–G49.7%—56.5%

Caveats

All conservation areas in Hackney · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker