Solar panels, heat pumps and insulation in Woodlands Grove conservation area

In the Woodlands Grove conservation area (Hounslow), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Hounslow covers this area but deals with other things (such as changes of use); it does not change the rules below. 140 homes inside the boundary have an energy certificate: 56.4% are solid-wall homes with no wall insulation, 85.0% heat with a gas boiler and 62.1% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

140homes with an energy certificate
56.4%solid walls, no insulation
85.0%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Hounslow covers this area but deals with other things (such as changes of use); it does not change the rules below. (Change of use or development that would result in new dwellings (Class MA/ZA); Dwellinghouses (C3) to small HMOs (C4) - borough-wide Article 4 Direction)

What needs planning permission in Woodlands Grove

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 140)

WallsHomesShare
Solid wall (brick or stone), no insulation7956.4%
Cavity wall, unfilled2719.3%
Cavity wall, filled96.4%
Cavity wall, insulated (as built or unspecified)85.7%
Cavity wall, partly insulated53.6%
Modern wall (U-value from the design)42.9%
Other or not known42.9%
Solid wall, insulated21.4%
Solid wall, partly insulated10.7%
Timber frame10.7%
HeatingHomesShare
Gas boiler11985.0%
Electric (storage heaters, panels, boiler)2014.3%
Communal heating10.7%
Loft / roof insulationHomesShare
No insulation1510.7%
Under 200 mm2618.6%
200 mm or more107.1%
Insulated (depth not recorded)1611.4%
Flat or other home above6949.3%
Other42.9%
WindowsHomesShare
Double glazed12790.7%
Single glazed107.1%
Secondary glazing21.4%
Triple glazed10.7%

Energy rating: B 1 (0.7%) · C 52 (37.1%) · D 55 (39.3%) · E 30 (21.4%) · F 2 (1.4%). Houses and bungalows: 20% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 2 November 1999.

Compared with Hounslow and England

Share of homesWoodlands GroveAll 29 areas in HounslowEngland
Solid walls, no insulation56.4%49.9%48.7%
Gas boiler85.0%77.4%66.4%
Rated D–G62.1%—56.5%

Caveats

All conservation areas in Hounslow · The rules for every conservation area