EPC Price Check

Solar panels, heat pumps and insulation in Steyning conservation area

In the Steyning conservation area (Horsham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 111 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 331 homes inside the boundary have an energy certificate: 55.9% are solid-wall homes with no wall insulation, 85.8% heat with a gas boiler and 74.9% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

331homes with an energy certificate
55.9%solid walls, no insulation
85.8%heated by a gas boiler
1heat pumps

Article 4: Horsham publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Steyning

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 331)

WallsHomesShare
Solid wall (brick or stone), no insulation18555.9%
Cavity wall, insulated (as built or unspecified)4714.2%
Cavity wall, unfilled267.9%
Modern wall (U-value from the design)226.6%
Cavity wall, filled216.3%
Timber frame103.0%
Solid wall, internal insulation82.4%
Solid wall, insulated72.1%
Cavity wall, partly insulated41.2%
Solid wall, partly insulated10.3%
HeatingHomesShare
Gas boiler28485.8%
Electric (storage heaters, panels, boiler)4413.3%
Communal heating10.3%
Heat pump10.3%
Solid fuel (wood, coal)10.3%
Loft / roof insulationHomesShare
No insulation6319.1%
Under 200 mm11133.6%
200 mm or more6218.8%
Insulated (depth not recorded)5316.1%
Flat or other home above185.5%
Other237.0%
WindowsHomesShare
Double glazed26379.5%
Single glazed5717.2%
Secondary glazing113.3%

Energy rating: B 7 (2.1%) · C 76 (23.0%) · D 147 (44.4%) · E 86 (26.0%) · F 10 (3.0%) · G 5 (1.5%). Houses and bungalows: 81% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 25 January 2018.

Compared with Horsham and England

Share of homesSteyningAll 40 areas in HorshamEngland
Solid walls, no insulation55.9%32.5%48.7%
Gas boiler85.8%67.6%66.4%
Rated D–G74.9%—56.5%