EPC Price Check

Solar panels, heat pumps and insulation in North Lancing conservation area

In the North Lancing conservation area (Adur), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 9 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 42 homes inside the boundary have an energy certificate: 26% are solid-wall homes with no wall insulation, 98% heat with a gas boiler and 98% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

42homes with an energy certificate
26%solid walls, no insulation
98%heated by a gas boiler
1heat pumps

Article 4: Adur publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in North Lancing

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 42)

WallsHomesShare
Cavity wall, filled1433%
Cavity wall, unfilled1331%
Solid wall (brick or stone), no insulation1126%
Cavity wall, partly insulated25%
Cavity wall, insulated (as built or unspecified)12%
Timber frame12%
HeatingHomesShare
Gas boiler4198%
Heat pump12%
Loft / roof insulationHomesShare
No insulation921%
Under 200 mm1229%
200 mm or more614%
Insulated (depth not recorded)1331%
Flat or other home above12%
Other12%
WindowsHomesShare
Double glazed4198%
Secondary glazing12%

Energy rating: C 1 (2%) · D 28 (67%) · E 12 (29%) · F 1 (2%). Houses and bungalows: 98% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 May 1975.

Compared with Adur and England

Share of homesNorth LancingAll 7 areas in AdurEngland
Solid walls, no insulation26%34.3%48.7%
Gas boiler98%78.1%66.4%
Rated D–G98%—56.5%

Caveats

All conservation areas in Adur · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker