EPC Price Check

Solar panels, heat pumps and insulation in Cornwallis Gardens, Hastings conservation area

In the Cornwallis Gardens, Hastings conservation area (Hastings), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 243 homes inside the boundary have an energy certificate: 83.5% are solid-wall homes with no wall insulation, 77.0% heat with a gas boiler and 72.4% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

243homes with an energy certificate
83.5%solid walls, no insulation
77.0%heated by a gas boiler
0heat pumps

Article 4: Hastings does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Cornwallis Gardens, Hastings

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 243)

WallsHomesShare
Solid wall (brick or stone), no insulation20383.5%
Timber frame135.3%
Cavity wall, filled83.3%
Solid wall, internal insulation52.1%
Solid wall, partly insulated52.1%
Cavity wall, insulated (as built or unspecified)31.2%
Cavity wall, unfilled31.2%
Modern wall (U-value from the design)20.8%
Solid wall, insulated10.4%
HeatingHomesShare
Gas boiler18777.0%
Electric (storage heaters, panels, boiler)5221.4%
Communal heating31.2%
LPG10.4%
Loft / roof insulationHomesShare
No insulation249.9%
Under 200 mm177.0%
200 mm or more93.7%
Insulated (depth not recorded)52.1%
Flat or other home above18576.1%
Other31.2%
WindowsHomesShare
Double glazed14660.1%
Single glazed9338.3%
Secondary glazing41.6%

Energy rating: B 3 (1.2%) · C 64 (26.3%) · D 124 (51.0%) · E 47 (19.3%) · F 4 (1.6%) · G 1 (0.4%). Houses and bungalows: 5% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900.

Compared with Hastings and England

Share of homesCornwallis Gardens, HastingsAll 18 areas in HastingsEngland
Solid walls, no insulation83.5%66.0%48.7%
Gas boiler77.0%70.3%66.4%
Rated D–G72.4%—56.5%

Caveats

All conservation areas in Hastings · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker