EPC Price Check

Solar panels, heat pumps and insulation in Old Harlow conservation area

In the Old Harlow conservation area (Harlow), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Harlow covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 37 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 347 homes inside the boundary have an energy certificate: 41.8% are solid-wall homes with no wall insulation, 80.4% heat with a gas boiler and 60.5% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

347homes with an energy certificate
41.8%solid walls, no insulation
80.4%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Harlow covers this area and removes permitted development rights for solar panels on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (HMO - townwide; High Street- 79-97 (odds); Old Harlow (Bury Road, New Road, High Street and Old Road); Park Hill and Mulberry Terrace)

What needs planning permission in Old Harlow

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 347)

WallsHomesShare
Solid wall (brick or stone), no insulation14541.8%
Modern wall (U-value from the design)4713.5%
Cavity wall, filled4613.3%
Timber frame349.8%
Cavity wall, insulated (as built or unspecified)277.8%
Cavity wall, unfilled267.5%
Other or not known133.7%
Cavity wall, partly insulated41.2%
Solid wall, insulated20.6%
Cavity wall, internal or external insulation10.3%
Solid wall, external insulation10.3%
Solid wall, internal insulation10.3%
HeatingHomesShare
Gas boiler27980.4%
Communal heating329.2%
Electric (storage heaters, panels, boiler)246.9%
Oil113.2%
LPG10.3%
Loft / roof insulationHomesShare
No insulation4312.4%
Under 200 mm7220.7%
200 mm or more10931.4%
Insulated (depth not recorded)3911.2%
Flat or other home above4111.8%
Other4312.4%
WindowsHomesShare
Double glazed27880.1%
Single glazed5215.0%
Secondary glazing144.0%
Other30.9%

Energy rating: B 34 (9.8%) · C 103 (29.7%) · D 142 (40.9%) · E 57 (16.4%) · F 11 (3.2%). Houses and bungalows: 68% of the homes; solar panels on 0.3% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1969.

Compared with Harlow and England

Share of homesOld HarlowAll 10 areas in HarlowEngland
Solid walls, no insulation41.8%26.1%48.7%
Gas boiler80.4%83.5%66.4%
Rated D–G60.5%—56.5%

Caveats

All conservation areas in Harlow · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker