EPC Price Check

Solar panels, heat pumps and insulation in No.9 Winterton conservation area

In the No.9 Winterton conservation area (Great Yarmouth), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Great Yarmouth covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 3 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 125 homes inside the boundary have an energy certificate: 58.4% are solid-wall homes with no wall insulation, 0.0% heat with a gas boiler and 90.4% are rated D–G; 12 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

125homes with an energy certificate
58.4%solid walls, no insulation
0.0%heated by a gas boiler
12heat pumps

Article 4: An Article 4 direction published by Great Yarmouth covers this area, but the published data does not say which rights it removes — check the direction before any work. (Article 4 Direction - Houses in Multiple Occupation Great Yarmouth; Article 4 Direction - Land to rear of 1 May Cottages, Winterton; Article 4 Direction - The Marrams Sandhills; Article 4 Direction - Winterton and Hemsby)

What needs planning permission in No.9 Winterton

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 125)

WallsHomesShare
Solid wall (brick or stone), no insulation7358.4%
Cavity wall, filled1310.4%
Cavity wall, insulated (as built or unspecified)1310.4%
Cavity wall, unfilled75.6%
Solid wall, internal insulation64.8%
Modern wall (U-value from the design)43.2%
Timber frame32.4%
Cavity wall, partly insulated21.6%
Solid wall, external insulation21.6%
Cavity wall, internal or external insulation10.8%
Solid wall, partly insulated10.8%
HeatingHomesShare
Oil6753.6%
Electric (storage heaters, panels, boiler)3326.4%
Heat pump129.6%
LPG64.8%
Solid fuel (wood, coal)64.8%
Communal heating10.8%
Loft / roof insulationHomesShare
No insulation129.6%
Under 200 mm2620.8%
200 mm or more6451.2%
Insulated (depth not recorded)1411.2%
Flat or other home above10.8%
Other86.4%
WindowsHomesShare
Double glazed12096.0%
Single glazed54.0%

Energy rating: B 3 (2.4%) · C 9 (7.2%) · D 36 (28.8%) · E 52 (41.6%) · F 19 (15.2%) · G 6 (4.8%). Houses and bungalows: 98% of the homes; solar panels on 2.4% of the certificates. Most common build period on the certificates: before 1900. Designated: 23 February 1979.

Compared with Great Yarmouth and England

Share of homesNo.9 WintertonAll 23 areas in Great YarmouthEngland
Solid walls, no insulation58.4%54.8%48.7%
Gas boiler0.0%49.8%66.4%
Rated D–G90.4%—56.5%

Caveats

All conservation areas in Great Yarmouth · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker