EPC Price Check

Solar panels, heat pumps and insulation in Wardington conservation area

In the Wardington conservation area (Cherwell), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 32 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 90 homes inside the boundary have an energy certificate: 67% are solid-wall homes with no wall insulation, 12% heat with a gas boiler and 90% are rated D–G; 7 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

90homes with an energy certificate
67%solid walls, no insulation
12%heated by a gas boiler
7heat pumps

Article 4: Cherwell does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Wardington

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 90)

WallsHomesShare
Solid wall (brick or stone), no insulation6067%
Cavity wall, insulated (as built or unspecified)1213%
Solid wall, internal insulation67%
Modern wall (U-value from the design)44%
Solid wall, insulated33%
Cavity wall, unfilled22%
Cavity wall, filled11%
Solid wall, partly insulated11%
Timber frame11%
HeatingHomesShare
Oil5258%
Electric (storage heaters, panels, boiler)1213%
Gas boiler1112%
Heat pump78%
LPG67%
Solid fuel (wood, coal)22%
Loft / roof insulationHomesShare
No insulation1416%
Under 200 mm2022%
200 mm or more1517%
Insulated (depth not recorded)3539%
Flat or other home above11%
Other56%
WindowsHomesShare
Double glazed8089%
Single glazed67%
Secondary glazing44%

Energy rating: B 1 (1%) · C 8 (9%) · D 33 (37%) · E 29 (32%) · F 16 (18%) · G 3 (3%). Houses and bungalows: 98% of the homes; solar panels on 0% of the certificates. Most common build period on the certificates: before 1900.

Compared with Cherwell and England

Share of homesWardingtonAll 60 areas in CherwellEngland
Solid walls, no insulation67%43.7%48.7%
Gas boiler12%58.8%66.4%
Rated D–G90%—56.5%

Caveats

All conservation areas in Cherwell · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker