EPC Price Check

Solar panels, heat pumps and insulation in Kings Cross St Pancras conservation area

In the Kings Cross St Pancras conservation area (Camden), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 42 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,013 homes inside the boundary have an energy certificate: 34.4% are solid-wall homes with no wall insulation, 40.2% heat with a gas boiler and 39.8% are rated D–G; 10 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,013homes with an energy certificate
34.4%solid walls, no insulation
40.2%heated by a gas boiler
10heat pumps

Article 4: An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. (Basements; Commercial, Business, and Service (Use Class E) to residential (Use Class C3) (in CAZ))

What needs planning permission in Kings Cross St Pancras

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,013)

WallsHomesShare
Modern wall (U-value from the design)41741.2%
Solid wall (brick or stone), no insulation34834.4%
Other or not known767.5%
Cavity wall, insulated (as built or unspecified)444.3%
Cavity wall, unfilled303.0%
Cavity wall, filled252.5%
Solid wall, insulated222.2%
Timber frame202.0%
Cavity wall, partly insulated80.8%
Solid wall, external insulation80.8%
Solid wall, internal insulation70.7%
Cavity wall, internal or external insulation40.4%
Solid wall, partly insulated40.4%
HeatingHomesShare
Gas boiler40740.2%
Communal heating39539.0%
Electric (storage heaters, panels, boiler)20119.8%
Heat pump101.0%
Loft / roof insulationHomesShare
No insulation777.6%
Under 200 mm444.3%
200 mm or more161.6%
Insulated (depth not recorded)787.7%
Flat or other home above69168.2%
Other10710.6%
WindowsHomesShare
Double glazed74873.8%
Single glazed20920.6%
Secondary glazing474.6%
Triple glazed90.9%

Energy rating: B 276 (27.2%) · C 334 (33.0%) · D 335 (33.1%) · E 56 (5.5%) · F 8 (0.8%) · G 4 (0.4%). Houses and bungalows: 7% of the homes; solar panels on 0.1% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 February 1994.

Compared with Camden and England

Share of homesKings Cross St PancrasAll 40 areas in CamdenEngland
Solid walls, no insulation34.4%67.1%48.7%
Gas boiler40.2%67.5%66.4%
Rated D–G39.8%—56.5%

Caveats

All conservation areas in Camden · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker