EPC Price Check

Solar panels, heat pumps and insulation in Regents Canal conservation area

In the Regents Canal conservation area (Camden), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 24 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 914 homes inside the boundary have an energy certificate: 14.3% are solid-wall homes with no wall insulation, 17.7% heat with a gas boiler and 9.0% are rated D–G; 52 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

914homes with an energy certificate
14.3%solid walls, no insulation
17.7%heated by a gas boiler
52heat pumps

Article 4: An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. (Basements; Commercial, Business, and Service (Use Class E) to residential (Use Class C3) (in CAZ))

What needs planning permission in Regents Canal

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 914)

WallsHomesShare
Modern wall (U-value from the design)32535.6%
Other or not known23325.5%
Cavity wall, insulated (as built or unspecified)14415.8%
Solid wall (brick or stone), no insulation13114.3%
Solid wall, insulated283.1%
Cavity wall, filled252.7%
Solid wall, internal insulation91.0%
Timber frame80.9%
Cavity wall, internal or external insulation40.4%
Cavity wall, unfilled30.3%
Cavity wall, partly insulated20.2%
Solid wall, external insulation10.1%
Solid wall, partly insulated10.1%
HeatingHomesShare
Communal heating57963.3%
Gas boiler16217.7%
Electric (storage heaters, panels, boiler)12113.2%
Heat pump525.7%
Loft / roof insulationHomesShare
No insulation242.6%
Under 200 mm141.5%
200 mm or more30.3%
Insulated (depth not recorded)748.1%
Flat or other home above71878.6%
Other818.9%
WindowsHomesShare
Double glazed83291.0%
Single glazed657.1%
Secondary glazing141.5%
Triple glazed20.2%
Other10.1%

Energy rating: B 553 (60.5%) · C 279 (30.5%) · D 67 (7.3%) · E 14 (1.5%) · F 1 (0.1%). Houses and bungalows: 3% of the homes; solar panels on 0.2% of the certificates. Most common build period on the certificates: 2007-2011. Designated: 1 March 1984.

Compared with Camden and England

Share of homesRegents CanalAll 40 areas in CamdenEngland
Solid walls, no insulation14.3%67.1%48.7%
Gas boiler17.7%67.5%66.4%
Rated D–G9.0%—56.5%

Caveats

All conservation areas in Camden · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker