Solar panels, heat pumps and insulation in Kite conservation area

In the Kite conservation area (Cambridge), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 45 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 849 homes inside the boundary have an energy certificate: 55.0% are solid-wall homes with no wall insulation, 67.7% heat with a gas boiler and 51.0% are rated D–G; 22 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

849homes with an energy certificate
55.0%solid walls, no insulation
67.7%heated by a gas boiler
22heat pumps

Article 4: Cambridge publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Kite

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 849)

WallsHomesShare
Solid wall (brick or stone), no insulation46755.0%
Cavity wall, insulated (as built or unspecified)12815.1%
Modern wall (U-value from the design)11513.5%
Other or not known758.8%
Solid wall, internal insulation212.5%
Cavity wall, internal or external insulation151.8%
Timber frame80.9%
Cavity wall, partly insulated70.8%
Cavity wall, unfilled50.6%
Cavity wall, filled40.5%
Solid wall, insulated40.5%
HeatingHomesShare
Gas boiler57567.7%
Communal heating15918.7%
Electric (storage heaters, panels, boiler)9010.6%
Heat pump222.6%
LPG20.2%
Oil10.1%
Loft / roof insulationHomesShare
No insulation10011.8%
Under 200 mm19222.6%
200 mm or more17821.0%
Insulated (depth not recorded)9511.2%
Flat or other home above21625.4%
Other688.0%
WindowsHomesShare
Double glazed58368.7%
Single glazed16719.7%
Secondary glazing9511.2%
Triple glazed30.4%
Other10.1%

Energy rating: A 1 (0.1%) · B 70 (8.2%) · C 345 (40.6%) · D 319 (37.6%) · E 102 (12.0%) · F 11 (1.3%) · G 1 (0.1%). Houses and bungalows: 57% of the homes; solar panels on 0.4% of the certificates. Most common build period on the certificates: before 1900. Designated: 21 November 2018.

Compared with Cambridge and England

Share of homesKiteAll 18 areas in CambridgeEngland
Solid walls, no insulation55.0%52.2%48.7%
Gas boiler67.7%71.7%66.4%
Rated D–G51.0%—56.5%