EPC Price Check

Solar panels, heat pumps and insulation in De Freville conservation area

In the De Freville conservation area (Cambridge), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 373 homes inside the boundary have an energy certificate: 77.5% are solid-wall homes with no wall insulation, 83.6% heat with a gas boiler and 75.3% are rated D–G; 5 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

373homes with an energy certificate
77.5%solid walls, no insulation
83.6%heated by a gas boiler
5heat pumps

Article 4: Cambridge publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in De Freville

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 373)

WallsHomesShare
Solid wall (brick or stone), no insulation28977.5%
Cavity wall, insulated (as built or unspecified)3810.2%
Timber frame133.5%
Solid wall, internal insulation92.4%
Modern wall (U-value from the design)82.1%
Cavity wall, filled71.9%
Cavity wall, partly insulated30.8%
Cavity wall, unfilled30.8%
Other or not known10.3%
Solid wall, external insulation10.3%
Solid wall, insulated10.3%
HeatingHomesShare
Gas boiler31283.6%
Electric (storage heaters, panels, boiler)4612.3%
Communal heating102.7%
Heat pump51.3%
Loft / roof insulationHomesShare
No insulation10728.7%
Under 200 mm6918.5%
200 mm or more6918.5%
Insulated (depth not recorded)7520.1%
Flat or other home above4512.1%
Other82.1%
WindowsHomesShare
Double glazed32286.3%
Single glazed349.1%
Secondary glazing154.0%
Triple glazed20.5%

Energy rating: B 17 (4.6%) · C 75 (20.1%) · D 176 (47.2%) · E 91 (24.4%) · F 11 (2.9%) · G 3 (0.8%). Houses and bungalows: 80% of the homes; solar panels on 1.6% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 3 March 2009.

Compared with Cambridge and England

Share of homesDe FrevilleAll 18 areas in CambridgeEngland
Solid walls, no insulation77.5%52.2%48.7%
Gas boiler83.6%71.7%66.4%
Rated D–G75.3%—56.5%

Caveats

All conservation areas in Cambridge · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker