EPC Price Check

Solar panels, heat pumps and insulation in Willesden Green conservation area

In the Willesden Green conservation area (Brent), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Brent covers this area and removes permitted development rights for solar panels on the house, wind turbines on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 4 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 757 homes inside the boundary have an energy certificate: 66.8% are solid-wall homes with no wall insulation, 67.0% heat with a gas boiler and 53.8% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

757homes with an energy certificate
66.8%solid walls, no insulation
67.0%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Brent covers this area and removes permitted development rights for solar panels on the house, wind turbines on the house, replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (Article 4 for HMOs; Article 4 for Town Centres - Willesden Green; Remainder of Borough; Willesden Green)

What needs planning permission in Willesden Green

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Planning permission needed (an Article 4 direction here removes this right)Part 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 757)

WallsHomesShare
Solid wall (brick or stone), no insulation50666.8%
Modern wall (U-value from the design)699.1%
Cavity wall, insulated (as built or unspecified)638.3%
Timber frame354.6%
Other or not known344.5%
Solid wall, internal insulation253.3%
Solid wall, insulated91.2%
Cavity wall, unfilled60.8%
Cavity wall, filled40.5%
Solid wall, external insulation30.4%
Cavity wall, internal or external insulation10.1%
Cavity wall, partly insulated10.1%
Solid wall, partly insulated10.1%
HeatingHomesShare
Gas boiler50767.0%
Electric (storage heaters, panels, boiler)12816.9%
Communal heating12116.0%
LPG10.1%
Loft / roof insulationHomesShare
No insulation13317.6%
Under 200 mm8210.8%
200 mm or more263.4%
Insulated (depth not recorded)648.5%
Flat or other home above40954.0%
Other435.7%
WindowsHomesShare
Double glazed66688.0%
Single glazed7910.4%
Secondary glazing101.3%
Triple glazed20.3%

Energy rating: B 73 (9.6%) · C 277 (36.6%) · D 315 (41.6%) · E 83 (11.0%) · F 5 (0.7%) · G 4 (0.5%). Houses and bungalows: 3% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 January 1993.

Compared with Brent and England

Share of homesWillesden GreenAll 23 areas in BrentEngland
Solid walls, no insulation66.8%77.8%48.7%
Gas boiler67.0%85.7%66.4%
Rated D–G53.8%—56.5%

Caveats

All conservation areas in Brent · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker