Solar panels, heat pumps and insulation in Moor Pool, Harborne conservation area

In the Moor Pool, Harborne conservation area (Birmingham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Birmingham covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 5 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 412 homes inside the boundary have an energy certificate: 92.7% are solid-wall homes with no wall insulation, 98.1% heat with a gas boiler and 82.3% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

412homes with an energy certificate
92.7%solid walls, no insulation
98.1%heated by a gas boiler
0heat pumps

Article 4: An Article 4 direction published by Birmingham covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (CITY WIDE HMO; MOOR POOL CONSERVATION AREA, ARTICLE 4(2))

What needs planning permission in Moor Pool, Harborne

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 412)

WallsHomesShare
Solid wall (brick or stone), no insulation38292.7%
Modern wall (U-value from the design)143.4%
Solid wall, internal insulation61.5%
Cavity wall, insulated (as built or unspecified)41.0%
Cavity wall, unfilled41.0%
Cavity wall, filled10.2%
Other or not known10.2%
HeatingHomesShare
Gas boiler40498.1%
Electric (storage heaters, panels, boiler)81.9%
Loft / roof insulationHomesShare
No insulation10124.5%
Under 200 mm12931.3%
200 mm or more13432.5%
Insulated (depth not recorded)266.3%
Flat or other home above81.9%
Other143.4%
WindowsHomesShare
Double glazed33180.3%
Single glazed7418.0%
Secondary glazing71.7%

Energy rating: B 15 (3.6%) · C 58 (14.1%) · D 237 (57.5%) · E 87 (21.1%) · F 13 (3.2%) · G 2 (0.5%). Houses and bungalows: 95% of the homes; solar panels on 0.2% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 30 July 1970.

Compared with Birmingham and England

Share of homesMoor Pool, HarborneAll 29 areas in BirminghamEngland
Solid walls, no insulation92.7%31.3%48.7%
Gas boiler98.1%46.8%66.4%
Rated D–G82.3%—56.5%