EPC Price Check

Solar panels, heat pumps and insulation in Edgbaston conservation area

In the Edgbaston conservation area (Birmingham), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Birmingham covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 288 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,947 homes inside the boundary have an energy certificate: 29.1% are solid-wall homes with no wall insulation, 77.6% heat with a gas boiler and 56.0% are rated D–G; 17 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,947homes with an energy certificate
29.1%solid walls, no insulation
77.6%heated by a gas boiler
17heat pumps

Article 4: An Article 4 direction published by Birmingham covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (CITY WIDE HMO; EDGBASTON CONSERVATION AREA, ARTICLE 4 (2))

What needs planning permission in Edgbaston

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,947)

WallsHomesShare
Solid wall (brick or stone), no insulation56629.1%
Cavity wall, unfilled37419.2%
Cavity wall, filled34817.9%
Cavity wall, insulated (as built or unspecified)20110.3%
Modern wall (U-value from the design)1929.9%
Timber frame924.7%
Cavity wall, partly insulated904.6%
Other or not known452.3%
Solid wall, internal insulation201.0%
Solid wall, insulated130.7%
Cavity wall, internal or external insulation40.2%
Solid wall, external insulation10.1%
Solid wall, partly insulated10.1%
HeatingHomesShare
Gas boiler1,51077.6%
Electric (storage heaters, panels, boiler)21611.1%
Communal heating20010.3%
Heat pump170.9%
Oil20.1%
Solid fuel (wood, coal)20.1%
Loft / roof insulationHomesShare
No insulation20810.7%
Under 200 mm21310.9%
200 mm or more23111.9%
Insulated (depth not recorded)31516.2%
Flat or other home above87444.9%
Other1065.4%
WindowsHomesShare
Double glazed1,50277.1%
Single glazed33417.2%
Secondary glazing1085.5%
Triple glazed30.2%

Energy rating: A 18 (0.9%) · B 191 (9.8%) · C 648 (33.3%) · D 747 (38.4%) · E 277 (14.2%) · F 53 (2.7%) · G 13 (0.7%). Houses and bungalows: 32% of the homes; solar panels on 0.1% of the certificates. Most common build period on the certificates: 1967-1975. Designated: 4 September 1975.

Compared with Birmingham and England

Share of homesEdgbastonAll 29 areas in BirminghamEngland
Solid walls, no insulation29.1%31.3%48.7%
Gas boiler77.6%46.8%66.4%
Rated D–G56.0%—56.5%

Caveats

All conservation areas in Birmingham · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker