EPC Price Check

Solar panels, heat pumps and insulation in Central Historic Core conservation area

In the Central Historic Core conservation area (York), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by York covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. The area has 1017 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 5,081 homes inside the boundary have an energy certificate: 39.4% are solid-wall homes with no wall insulation, 51.8% heat with a gas boiler and 46.2% are rated D–G; 42 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

5,081homes with an energy certificate
39.4%solid walls, no insulation
51.8%heated by a gas boiler
42heat pumps

Article 4: An Article 4 direction published by York covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, alterations to the roof (e.g. rooflights), chimneys, flues and soil pipes, painting the outside, so there these need planning permission too. (East Mount Road; HMO)

What needs planning permission in Central Historic Core

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 5,081)

WallsHomesShare
Solid wall (brick or stone), no insulation2,00239.4%
Cavity wall, insulated (as built or unspecified)1,31225.8%
Modern wall (U-value from the design)75714.9%
Cavity wall, filled2935.8%
Solid wall, insulated1783.5%
Timber frame1633.2%
Solid wall, internal insulation1182.3%
Other or not known951.9%
Cavity wall, partly insulated701.4%
Cavity wall, unfilled691.4%
Cavity wall, internal or external insulation150.3%
Solid wall, partly insulated90.2%
HeatingHomesShare
Gas boiler2,63151.8%
Electric (storage heaters, panels, boiler)2,08641.1%
Communal heating3025.9%
Heat pump420.8%
LPG190.4%
Oil10.0%
Loft / roof insulationHomesShare
No insulation4769.4%
Under 200 mm58911.6%
200 mm or more75514.9%
Insulated (depth not recorded)57111.2%
Flat or other home above2,40047.2%
Other2905.7%
WindowsHomesShare
Double glazed3,82475.3%
Single glazed88917.5%
Secondary glazing3607.1%
Triple glazed70.1%
Other10.0%

Energy rating: A 2 (0.0%) · B 598 (11.8%) · C 2,136 (42.0%) · D 1,644 (32.4%) · E 597 (11.7%) · F 75 (1.5%) · G 29 (0.6%). Houses and bungalows: 27% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1968.

Compared with York and England

Share of homesCentral Historic CoreAll 35 areas in YorkEngland
Solid walls, no insulation39.4%37.5%48.7%
Gas boiler51.8%61.7%66.4%
Rated D–G46.2%—56.5%

Caveats

All conservation areas in York · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker