Solar panels, heat pumps and insulation in Stourport-on-Severn No. 1 conservation area
In the Stourport-on-Severn No. 1 conservation area (Wyre Forest), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 40 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 264 homes inside the boundary have an energy certificate: 20.1% are solid-wall homes with no wall insulation, 44.3% heat with a gas boiler and 38.3% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.
Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources
264homes with an energy certificate
20.1%solid walls, no insulation
44.3%heated by a gas boiler
0heat pumps
Article 4: Wyre Forest does not publish Article 4 areas on planning.data.gov.uk — check with the council.
What needs planning permission in Stourport-on-Severn No. 1
Work (house, not listed)
In a conservation area
Rule
Air source heat pump on a wall or roof facing the road, or nearer the road than the house
Planning permission needed
Part 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the road
Planning permission needed
Part 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)
Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the council
Replacement windows and doors of similar appearance
No permission needed (permitted development), unless an Article 4 direction removes it — check with the council
Part 1 Class A, A.3(a)
Listed buildings: 40 in the area (grade I: 0, II*: 1). The table is for houses that are not listed: on a listed building, solar panels and air source heat pumps are not permitted development at all (they need planning permission), and any of these works needs listed building consent.
Flats: 73% of the certified homes here are flats or maisonettes. Homes in a block of flats have no householder rights for alterations; heat pumps and solar have their own, tighter rules for blocks of flats.
The homes in the area (latest certificate per home, n = 264)
Walls
Homes
Share
Cavity wall, insulated (as built or unspecified)
116
43.9%
Solid wall (brick or stone), no insulation
53
20.1%
Modern wall (U-value from the design)
52
19.7%
Solid wall, internal insulation
17
6.4%
Solid wall, insulated
7
2.7%
Cavity wall, filled
6
2.3%
Other or not known
5
1.9%
Cavity wall, partly insulated
2
0.8%
Cavity wall, unfilled
2
0.8%
Solid wall, partly insulated
2
0.8%
Timber frame
2
0.8%
Heating
Homes
Share
Electric (storage heaters, panels, boiler)
147
55.7%
Gas boiler
117
44.3%
Loft / roof insulation
Homes
Share
No insulation
10
3.8%
Under 200 mm
21
8.0%
200 mm or more
44
16.7%
Insulated (depth not recorded)
30
11.4%
Flat or other home above
127
48.1%
Other
32
12.1%
Windows
Homes
Share
Double glazed
215
81.4%
Single glazed
36
13.6%
Secondary glazing
8
3.0%
Other
5
1.9%
BCDE
Energy rating: B 23 (8.7%) · C 140 (53.0%) · D 72 (27.3%) · E 22 (8.3%) · F 4 (1.5%) · G 3 (1.1%). Houses and bungalows: 27% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 2007-2011. Designated: 1 January 1970.
Compared with Wyre Forest and England
Share of homes
Stourport-on-Severn No. 1
All 17 areas in Wyre Forest
England
Solid walls, no insulation
20.1%
49.0%
48.7%
Gas boiler
44.3%
63.2%
66.4%
Rated D–G
38.3%
—
56.5%
Caveats
Certificates describe a home when it was assessed; 60% of these are from 2020 or later (latest 22 October 2026). “No insulation (assumed)” is the assessor's default for older walls.
The rules are England's national permitted development rules (General Permitted Development Order 2015, Schedule 2, as at 21 October 2026). They do not cover building regulations or a council's own conditions. This is not a planning decision: ask Wyre Forest if in doubt.
Boundary: Wyre Forest District Council via planning.data.gov.uk (entity 44006348, reference 9105, 17.0 ha); the council's appraisal or map. Homes are placed by the coordinates of their UPRN (OS Open UPRN); addresses are not shown.