EPC Price Check

Solar panels, heat pumps and insulation in Wellington Road conservation area

In the Wellington Road conservation area (Wirral), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 9 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 145 homes inside the boundary have an energy certificate: 71.7% are solid-wall homes with no wall insulation, 44.8% heat with a gas boiler and 40.7% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

145homes with an energy certificate
71.7%solid walls, no insulation
44.8%heated by a gas boiler
0heat pumps

Article 4: Wirral publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Wellington Road

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 145)

WallsHomesShare
Solid wall (brick or stone), no insulation10471.7%
Solid wall, internal insulation2416.6%
Cavity wall, unfilled85.5%
Other or not known53.4%
Modern wall (U-value from the design)21.4%
Cavity wall, insulated (as built or unspecified)10.7%
Solid wall, partly insulated10.7%
HeatingHomesShare
Communal heating6645.5%
Gas boiler6544.8%
Electric (storage heaters, panels, boiler)149.7%
Loft / roof insulationHomesShare
No insulation2013.8%
Under 200 mm53.4%
200 mm or more106.9%
Insulated (depth not recorded)53.4%
Flat or other home above10371.0%
Other21.4%
WindowsHomesShare
Double glazed13794.5%
Single glazed74.8%
Secondary glazing10.7%

Energy rating: B 6 (4.1%) · C 80 (55.2%) · D 46 (31.7%) · E 11 (7.6%) · G 2 (1.4%). Houses and bungalows: 6% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 December 1973.

Compared with Wirral and England

Share of homesWellington RoadAll 26 areas in WirralEngland
Solid walls, no insulation71.7%53.5%48.7%
Gas boiler44.8%80.2%66.4%
Rated D–G40.7%—56.5%

Caveats

All conservation areas in Wirral · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker