EPC Price Check

Solar panels, heat pumps and insulation in North Vickerstown conservation area

In the North Vickerstown conservation area (Westmorland and Furness), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 425 homes inside the boundary have an energy certificate: 3.5% are solid-wall homes with no wall insulation, 89.4% heat with a gas boiler and 72.0% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

425homes with an energy certificate
3.5%solid walls, no insulation
89.4%heated by a gas boiler
0heat pumps

Article 4: Westmorland and Furness does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in North Vickerstown

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 425)

WallsHomesShare
Cavity wall, unfilled24357.2%
Cavity wall, filled10624.9%
Modern wall (U-value from the design)235.4%
Cavity wall, partly insulated174.0%
Solid wall (brick or stone), no insulation153.5%
Cavity wall, insulated (as built or unspecified)143.3%
Timber frame51.2%
Cavity wall, internal or external insulation20.5%
HeatingHomesShare
Gas boiler38089.4%
Electric (storage heaters, panels, boiler)4310.1%
Communal heating10.2%
Solid fuel (wood, coal)10.2%
Loft / roof insulationHomesShare
No insulation11025.9%
Under 200 mm11627.3%
200 mm or more11827.8%
Insulated (depth not recorded)296.8%
Flat or other home above307.1%
Other225.2%
WindowsHomesShare
Double glazed41898.4%
Single glazed71.6%

Energy rating: B 24 (5.6%) · C 95 (22.4%) · D 226 (53.2%) · E 65 (15.3%) · F 14 (3.3%) · G 1 (0.2%). Houses and bungalows: 88% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929.

Compared with Westmorland and Furness and England

Share of homesNorth VickerstownAll 51 areas in Westmorland and FurnessEngland
Solid walls, no insulation3.5%51.1%48.7%
Gas boiler89.4%69.6%66.4%
Rated D–G72.0%—56.5%

Caveats

All conservation areas in Westmorland and Furness · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker