EPC Price Check

Solar panels, heat pumps and insulation in East Marylebone conservation area

In the East Marylebone conservation area (Westminster), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Westminster covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. The area has 43 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,455 homes inside the boundary have an energy certificate: 51.8% are solid-wall homes with no wall insulation, 55.6% heat with a gas boiler and 33.5% are rated D–G; 53 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,455homes with an energy certificate
51.8%solid walls, no insulation
55.6%heated by a gas boiler
53heat pumps

Article 4: An Article 4 direction published by Westminster covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. (Article 4 Basement Development Permitted Rights Removed; Article 4 Direction Class E To C3 In Central Activities Zone)

What needs planning permission in East Marylebone

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,455)

WallsHomesShare
Solid wall (brick or stone), no insulation75451.8%
Modern wall (U-value from the design)28019.2%
Other or not known14510.0%
Cavity wall, insulated (as built or unspecified)704.8%
Timber frame664.5%
Solid wall, insulated553.8%
Solid wall, internal insulation513.5%
Solid wall, partly insulated100.7%
Cavity wall, unfilled80.5%
Solid wall, external insulation60.4%
Cavity wall, filled40.3%
Cavity wall, internal or external insulation30.2%
Cavity wall, partly insulated30.2%
HeatingHomesShare
Gas boiler80955.6%
Communal heating42729.3%
Electric (storage heaters, panels, boiler)16511.3%
Heat pump533.6%
Solid fuel (wood, coal)10.1%
Loft / roof insulationHomesShare
No insulation1218.3%
Under 200 mm221.5%
200 mm or more130.9%
Insulated (depth not recorded)946.5%
Flat or other home above1,08974.8%
Other1168.0%
WindowsHomesShare
Double glazed82756.8%
Single glazed49934.3%
Secondary glazing1198.2%
Triple glazed100.7%

Energy rating: B 338 (23.2%) · C 630 (43.3%) · D 381 (26.2%) · E 95 (6.5%) · F 9 (0.6%) · G 2 (0.1%). Houses and bungalows: 2% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 20 November 1990.

Compared with Westminster and England

Share of homesEast MaryleboneAll 56 areas in WestminsterEngland
Solid walls, no insulation51.8%66.4%48.7%
Gas boiler55.6%59.2%66.4%
Rated D–G33.5%—56.5%

Caveats

All conservation areas in Westminster · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker