In the Oxhey conservation area (Watford), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 380 homes inside the boundary have an energy certificate: 77.4% are solid-wall homes with no wall insulation, 93.7% heat with a gas boiler and 76.3% are rated D–G; 4 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

380homes with an energy certificate
77.4%solid walls, no insulation
93.7%heated by a gas boiler
4heat pumps

Article 4: Watford does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Oxhey

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 380)

WallsHomesShare
Solid wall (brick or stone), no insulation29477.4%
Cavity wall, insulated (as built or unspecified)338.7%
Modern wall (U-value from the design)205.3%
Cavity wall, unfilled153.9%
Cavity wall, filled82.1%
Solid wall, internal insulation51.3%
Solid wall, insulated30.8%
Cavity wall, partly insulated10.3%
Other or not known10.3%
HeatingHomesShare
Gas boiler35693.7%
Electric (storage heaters, panels, boiler)195.0%
Heat pump41.1%
Communal heating10.3%
Loft / roof insulationHomesShare
No insulation7419.5%
Under 200 mm17345.5%
200 mm or more6617.4%
Insulated (depth not recorded)338.7%
Flat or other home above236.1%
Other112.9%
WindowsHomesShare
Double glazed36295.3%
Single glazed143.7%
Secondary glazing30.8%
Triple glazed10.3%

Energy rating: B 13 (3.4%) · C 77 (20.3%) · D 210 (55.3%) · E 69 (18.2%) · F 10 (2.6%) · G 1 (0.3%). Houses and bungalows: 87% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 2013.

Compared with Watford and England

Share of homesOxheyAll 10 areas in WatfordEngland
Solid walls, no insulation77.4%56.5%48.7%
Gas boiler93.7%76.7%66.4%
Rated D–G76.3%—56.5%