EPC Price Check

Solar panels, heat pumps and insulation in Sutherland Grove conservation area

In the Sutherland Grove conservation area (Wandsworth), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 5 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 670 homes inside the boundary have an energy certificate: 40.7% are solid-wall homes with no wall insulation, 74.8% heat with a gas boiler and 44.5% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

670homes with an energy certificate
40.7%solid walls, no insulation
74.8%heated by a gas boiler
1heat pumps

Article 4: Wandsworth does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Sutherland Grove

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 670)

WallsHomesShare
Solid wall (brick or stone), no insulation27340.7%
Other or not known14822.1%
Cavity wall, insulated (as built or unspecified)12919.3%
Solid wall, insulated446.6%
Timber frame345.1%
Solid wall, internal insulation172.5%
Cavity wall, unfilled91.3%
Cavity wall, filled40.6%
Cavity wall, partly insulated40.6%
Modern wall (U-value from the design)30.4%
Solid wall, partly insulated30.4%
Cavity wall, internal or external insulation20.3%
HeatingHomesShare
Gas boiler50174.8%
Electric (storage heaters, panels, boiler)16124.0%
Communal heating60.9%
Heat pump10.1%
LPG10.1%
Loft / roof insulationHomesShare
No insulation8813.1%
Under 200 mm6710.0%
200 mm or more669.9%
Insulated (depth not recorded)11817.6%
Flat or other home above32748.8%
Other40.6%
WindowsHomesShare
Double glazed55382.5%
Single glazed10415.5%
Secondary glazing91.3%
Triple glazed40.6%

Energy rating: B 142 (21.2%) · C 230 (34.3%) · D 189 (28.2%) · E 74 (11.0%) · F 25 (3.7%) · G 10 (1.5%). Houses and bungalows: 37% of the homes; solar panels on 0.4% of the certificates. Most common build period on the certificates: 2003-2006. Designated: 23 November 1992.

Compared with Wandsworth and England

Share of homesSutherland GroveAll 47 areas in WandsworthEngland
Solid walls, no insulation40.7%62.1%48.7%
Gas boiler74.8%81.0%66.4%
Rated D–G44.5%—56.5%

Caveats

All conservation areas in Wandsworth · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker