Solar panels, heat pumps and insulation in Landford Road conservation area

In the Landford Road conservation area (Wandsworth), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. 374 homes inside the boundary have an energy certificate: 86.9% are solid-wall homes with no wall insulation, 96.5% heat with a gas boiler and 79.7% are rated D–G; 2 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

374homes with an energy certificate
86.9%solid walls, no insulation
96.5%heated by a gas boiler
2heat pumps

Article 4: Wandsworth does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Landford Road

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 374)

WallsHomesShare
Solid wall (brick or stone), no insulation32586.9%
Cavity wall, insulated (as built or unspecified)236.1%
Timber frame102.7%
Solid wall, insulated41.1%
Solid wall, internal insulation41.1%
Cavity wall, unfilled30.8%
Other or not known20.5%
Cavity wall, filled10.3%
Cavity wall, partly insulated10.3%
Modern wall (U-value from the design)10.3%
HeatingHomesShare
Gas boiler36196.5%
Electric (storage heaters, panels, boiler)92.4%
Heat pump20.5%
Communal heating10.3%
LPG10.3%
Loft / roof insulationHomesShare
No insulation11230.0%
Under 200 mm6316.9%
200 mm or more246.4%
Insulated (depth not recorded)8422.5%
Flat or other home above8923.9%
Other10.3%
WindowsHomesShare
Double glazed29478.6%
Single glazed7319.5%
Secondary glazing71.9%

Energy rating: A 1 (0.3%) · B 6 (1.6%) · C 69 (18.4%) · D 168 (44.9%) · E 104 (27.8%) · F 23 (6.1%) · G 3 (0.8%). Houses and bungalows: 62% of the homes; solar panels on 0.3% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 2 March 2009.

Compared with Wandsworth and England

Share of homesLandford RoadAll 47 areas in WandsworthEngland
Solid walls, no insulation86.9%62.1%48.7%
Gas boiler96.5%81.0%66.4%
Rated D–G79.7%—56.5%

Caveats

All conservation areas in Wandsworth · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker