EPC Price Check

Solar panels, heat pumps and insulation in Arboretum conservation area

In the Arboretum conservation area (Walsall), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 7 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 313 homes inside the boundary have an energy certificate: 46.0% are solid-wall homes with no wall insulation, 53.0% heat with a gas boiler and 56.2% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

313homes with an energy certificate
46.0%solid walls, no insulation
53.0%heated by a gas boiler
0heat pumps

Article 4: Walsall does not publish Article 4 areas on planning.data.gov.uk — check with the council.

What needs planning permission in Arboretum

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 313)

WallsHomesShare
Solid wall (brick or stone), no insulation14446.0%
Cavity wall, filled4915.7%
Cavity wall, insulated (as built or unspecified)4113.1%
Modern wall (U-value from the design)3812.1%
Solid wall, internal insulation154.8%
Cavity wall, unfilled103.2%
Cavity wall, partly insulated82.6%
Timber frame41.3%
Cavity wall, internal or external insulation10.3%
Other or not known10.3%
Solid wall, external insulation10.3%
Solid wall, insulated10.3%
HeatingHomesShare
Gas boiler16653.0%
Electric (storage heaters, panels, boiler)13944.4%
Communal heating82.6%
Loft / roof insulationHomesShare
No insulation4313.7%
Under 200 mm268.3%
200 mm or more4113.1%
Insulated (depth not recorded)3611.5%
Flat or other home above15649.8%
Other113.5%
WindowsHomesShare
Double glazed26484.3%
Single glazed3812.1%
Secondary glazing103.2%
Triple glazed10.3%

Energy rating: B 33 (10.5%) · C 104 (33.2%) · D 80 (25.6%) · E 74 (23.6%) · F 17 (5.4%) · G 5 (1.6%). Houses and bungalows: 22% of the homes; solar panels on 0.3% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 19 April 1989.

Compared with Walsall and England

Share of homesArboretumAll 18 areas in WalsallEngland
Solid walls, no insulation46.0%30.9%48.7%
Gas boiler53.0%60.8%66.4%
Rated D–G56.2%—56.5%

Caveats

All conservation areas in Walsall · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker