EPC Price Check

Solar panels, heat pumps and insulation in Stansted Mountfitchet (CONARA/221) conservation area

In the Stansted Mountfitchet conservation area (Uttlesford), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Uttlesford covers part of this area (about 6% of it), but the published data does not say which rights it removes — check the direction before any work. The area has 67 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 303 homes inside the boundary have an energy certificate: 49.5% are solid-wall homes with no wall insulation, 82.8% heat with a gas boiler and 62.7% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

303homes with an energy certificate
49.5%solid walls, no insulation
82.8%heated by a gas boiler
1heat pumps

Article 4: An Article 4 direction published by Uttlesford covers part of this area (about 6% of it), but the published data does not say which rights it removes — check the direction before any work. (2 Bentfield End Causeway Stansted; Confirmed - Stansted Con Area Town & County Planning; Multiple Addresses in Stansted)

What needs planning permission in Stansted Mountfitchet

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 303)

WallsHomesShare
Solid wall (brick or stone), no insulation15049.5%
Cavity wall, insulated (as built or unspecified)7023.1%
Timber frame3912.9%
Modern wall (U-value from the design)196.3%
Solid wall, insulated72.3%
Solid wall, internal insulation62.0%
Cavity wall, unfilled51.7%
Other or not known41.3%
Cavity wall, partly insulated20.7%
Cavity wall, filled10.3%
HeatingHomesShare
Gas boiler25182.8%
Electric (storage heaters, panels, boiler)4715.5%
Communal heating31.0%
Heat pump10.3%
Oil10.3%
Loft / roof insulationHomesShare
No insulation3210.6%
Under 200 mm7725.4%
200 mm or more5317.5%
Insulated (depth not recorded)5718.8%
Flat or other home above6220.5%
Other227.3%
WindowsHomesShare
Double glazed22975.6%
Single glazed5016.5%
Secondary glazing247.9%

Energy rating: B 38 (12.5%) · C 75 (24.8%) · D 109 (36.0%) · E 65 (21.5%) · F 12 (4.0%) · G 4 (1.3%). Houses and bungalows: 63% of the homes; solar panels on 1.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 20 March 2008.

Compared with Uttlesford and England

Share of homesStansted MountfitchetAll 42 areas in UttlesfordEngland
Solid walls, no insulation49.5%31.3%48.7%
Gas boiler82.8%70.9%66.4%
Rated D–G62.7%—56.5%

Caveats

All conservation areas in Uttlesford · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker